Alcatel-Lucent 7705 SAR-8 System Management Manual page 252

Service aggregation router os
Table of Contents

Advertisement

Log Command Reference
event-name | event-number — to generate, suppress, or revert to default for a single event, enter the
generate — specifies that logger event is created when this event occurs. The generate keyword can
severity-level — An ASCII string representing the severity level to associate with the specified
throttle — specifies whether events of this type will be throttled.
suppress — indicates that the specified events will not be logged. If the suppress keyword is not
throttle-rate
Syntax
throttle-rate events [interval seconds]
no throttle-rate
Context
config>log
Description
This command configures an event throttling rate.
Parameters
events — specifies the number of log events that can be logged within the specified interval for a
interval seconds — specifies the number of seconds that an event throttling interval lasts
Page 252
specific number or event short name. If no event number or name is specified, the command
applies to all events in the application. To display a list of all event short names use the event-
control command.
Default
none
Values
A valid event name or event number.
be used with two optional parameters, severity-level and throttle.
Default
generate
generated events
Default
The system assigned severity level
Values
One of: cleared, indeterminate, critical, major, minor, warning
By default, event throttling is off for each specific event type. It must be explicitly enabled for
each event type where throttling is desired. This makes backwards compatability easier to
manage.
specified, then the events are generated by default.
Default
generate
specific event. Once the limit has been reached, any additional events of that type will be
dropped, and the event drop count will be incremented. At the end of the throttle interval, if any
events have been dropped, a trap notification will be sent.
Values
10 to 20000
Default
500
Values
1 to 60
Default
1