SECTION THREE – COMMANDS
304Plus CTD to acknowledge receipt of a portion of firmware. This procedure continues until
the end of the OceanSeven304Plus_xxx.txt file is reached. The end of the firmware transfer is
easily acknowledged by the automatic closure of the ITERM "File Transfer" window.
7.
When this happens and if everything has gone well, the OS304Plus CTD will restart by itself
showing the main menu. The OS304Plus firmware has been upgraded.
8.
Sometimes and independently of the successfully completion of the firmware upgrading
procedure, the CTD does not restart by itself immediately. If this happens, please switch it
OFF and then ON respecting the 30s delay between the OFF-ON cycles. The CTD will restart
and, if the following firmware upgrading message appears again:
OS3xxPlus-Bootloader[v3 03/2013]<^C-Abort> <SPACE-New Firmware>
type CTRL-C to start with the new firmware. If the CTD Main Menu appears, the procedure is
completed.
Otherwise, if the above message appears again, repeat the firmware upgrading
procedure starting from point 2 above.
Note
 This procedure cannot be interrupted or aborted; after you've run it, you must complete it as described,
otherwise the OS304Plus device will not operate properly.
 Please be sure that the OS304Plus power source is stable and never interrupted during the firmware
upgrading.
 Please be sure that the connected PC is well powered and do not run any other software during the firmware
upgrading procedure.
 The firmware upgrading procedure should take about 10 minutes at the maximum.
In case the firmware upgrading procedure is not well performed and after switching on/off the CTD,
the main menu does not appear, nor is the above message in point (2) shown, contact Idronaut to
receive the further instructions.
The OCEAN SEVEN 304Plus communication speed can now be returned to the default value of
38400bps reverting the above described procedure!

3.5.6. Diagnostics

Access to the diagnostic functions of the CTD electronic board is protected by ADMINISTRATIVE
rights. The description of these functions is out of the scope of this Operator's Manual. Contact
IDRONAUT to obtain detailed information.
3.6.

CHANGE OPERATING MODE

This command allows the operator to change the OCEAN SEVEN 304Plus CTD operating mode from
"Verbose" to "Non Verbose".
IDRONAUT – Brugherio (MB)
OCEAN SEVEN 304Plus CTD
32
12-2015