Sign In
Upload
Manuals
Brands
idronaut Manuals
Accessories
Ocean Seven 310
idronaut Ocean Seven 310 CTD Manuals
Manuals and User Guides for idronaut Ocean Seven 310 CTD. We have
1
idronaut Ocean Seven 310 CTD manual available for free PDF download: Operator's Manual
idronaut Ocean Seven 310 Operator's Manual (139 pages)
Multi-parameter CTD
Brand:
idronaut
| Category:
Accessories
| Size: 2 MB
Table of Contents
Table of Contents
8
1 Introduction
12
Probe Description
12
Sampling Modes
13
Real-Time Communications
13
WIRELESS COMMUNICATION MODULE "BLUETOOTH ® ", "Wifi
14
Portable Reader
14
Idronaut Telemetry Deck Unit
14
Internal Batteries
15
External Submersible Rechargeable Battery Packs
15
Magnetic Power On/Off Switch
15
Management Programmes
16
Standard Sensor Specifications
17
Optional Sensor Specifications
17
Electronic Specifications
17
Physical Characteristics
18
The Standard Sensors
18
Lifetime and How to Replace the Idronaut Sensors
18
The Pressure Sensor
18
The Temperature Sensor
19
The Conductivity Sensor Equipped with the "IDRONAUT Seven-Ring Cell
19
The Oxygen Sensor (Standard 150Bar and 700 Bar Versions)
20
The Oxygen Sensor Maintenance-Free Version - 5 Bar Only
21
Blue Cap Optical Dissolved Oxygen
22
Ph and Reference Sensors
22
The Redox Sensor
24
Calculations
25
Polarographic Oxygen Sensor
25
Ph Calculation and Ph Correction in Relation to the Sample Temperature
25
Conductivity Compensated at 20 °C
26
Probe Firmware Overview
27
User Interface
27
Menu & Submenu Structure
28
Menu Header Structure
28
Probe Access Rights
29
Data Transmission Protocol
29
Data Transmission Protocol: PTP Point-To-Point
29
Acquired Data Processing and Post-Processing
30
Low Power Consumption
30
Configuration
30
2 Installation and Start up
32
Shipping List
32
Laboratory RS232C Cable
32
Installation
32
Internal and External Battery Packs
32
Telemetry Deck Unit Installation
33
Start-Up
33
RS232C/RS485 Interface - Probe Power on
33
Telemetry Interface Probe Power on
33
Standard Start-Up Messages
33
The Main Menu
34
Low Power Consumption
35
3 Data Acquisition
36
The Data Acquisition Menu
36
Acquired Parameters
36
Common Rules to Set up the Data Acquisition Cycle
36
Commmon Rules to Store Acquired Data
36
On-Line Acknowledgement
37
Unattended Acknowledgement
37
Uploading Data Stored in the Probe Memory
37
Unattended Acquisitions - Important Tips
37
Power Consumption Reduction
38
Warm-Up
38
ON/OFF Cycles
38
Shipping Conditions
38
Sensors
38
Real Time Data Acquisition
38
Linear Data Acquisition
39
Routine Operations to Perform Unattended Linear Profiles
39
Terminate the Unattended Linear Profile
40
Step-By-Step Linear Profile Procedure
40
Timed Data Acquisition
42
Terminate a Timed Data Acquisition
43
Automatic Power off Procedure
44
Accidental Power on Cycle
44
Magnetic Power ON/OFF Switch
44
Step-By-Step Procedure
44
Conditional Data Acquisition
46
Terminate the Conditional Data Acquisition
47
Continuous Data Acquisition
49
Step-By-Step Procedure
49
Routine Operations to Perform Unattended Continuous Profiles
50
Terminate the Continuous Data Acquisition
50
Burst Data Acquisition
52
Field Operations
52
Ending the Unattended Data Acquisitions
52
4 Data Storage
54
Memory Organization
54
Cast Area
54
Data Records
54
Data Sets
55
Memory Management
55
Show Memory Status
55
Show Stored Data
55
Memory Delete Data
56
Initialize Data Memory
56
5 Sensor Calibration
58
Calibration Storing Layout
58
Parameter/Sensor Logical Codes
58
Calibration Glp (Good Laboratory Practice)
58
Sensor Calibration Functions
58
Updating the Calibration Information
59
Calibrate the Sensors
59
Selecting a Wrong Sensor
59
Customized Calibration Procedure
59
Pressure Sensor
60
Temperature & Conductivity Sensor Calibration
60
Simple Check of Conductivity Sensor Calibration
61
Oxygen Sensor Calibration
61
Ph Sensor Calibration
63
Redox Sensor Calibration
64
Extended Calibration Procedures
65
SEAPOINT OEM Turbidity Meter
66
SEAPOINT OEM Fluorometer
67
Wetlabs - C-STAR Transmissometer
67
Wetlabs - ECO Triplet Sensor
69
LICOR - PAR Sensor
70
Single/Three-Channel Fluorimeter
72
TURNER DESIGNS - CYCLOPS-7 Calibration Coefficients
74
Calibrating Logging
74
6 Service, Diagnostics and Configuration
75
The Service Menu
75
Raw Data Acquisition in ADC Counts or MV
75
Probe Diagnostic Functions
75
Probe Configuration
77
7 Probe Maintenance
82
Oxygen Sensor
82
Important Remark on Oxygen Measurement
82
Green Membrane
82
Refilling Oxygen Sensor Cap with Electrolyte
83
Membrane Replacement (Oxygen Membrane Cap)
83
Replacement of Membrane(S) Using the OXYGEN SENSOR MAINTENANCE KIT
83
Oxygen Sensor Cleaning
84
Oxygen Sensor Check in the Absence of Oxygen
85
Reference Sensor
85
Ph SENSOR
85
To Etch the Sensor, Perform the Following
86
Important Remark on the Ph Measurement
86
Conductivity Sensor
86
Important Remarks on Conductivity Measurement
86
Conductivity Sensor Cleaning
87
Advertisement
Advertisement
Related Products
idronaut Ocean Seven 307
idronaut Ocean Seven 311
idronaut Ocean Seven 303Plus
idronaut Ocean Seven 304Plus
idronaut OCEAN SEVEN 306
idronaut Ocean Seven 314
idronaut OCEAN SEVEN 315
idronaut Ocean Seven 316 Plus CTD
idronaut Categories
Accessories
Measuring Instruments
Control Unit
More idronaut Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL