AutomationDrive FC 300, P30KT4
Cable
AC line
length [m]
voltage
5
480
50
480
100
480
150
480
AutomationDrive FC 300, P37KT4
Cable
AC line
length [m]
voltage [V]
5
480
50
480
100
480
150
480
AutomationDrive FC 300, P45KT4
Cable
AC line
length [m]
voltage [V]
15
480
50
480
100
480
150
480
AutomationDrive FC 300, P55KT5
Cable
AC line
length [m]
voltage [V]
5
480
AutomationDrive FC 300, P75KT5
Cable
AC line
length [m]
voltage [V]
5
480
High Power range:
The power sizes below at the appropriate AC line voltages comply with the requirements of IEC 60034-17 regarding normal motors controlled by adjustable
frequency drives, IEC 60034-25 regarding motors designed to be controlled by adjustable frequency drives, and NEMA MG 1-1998 Part 31.4.4.2 for
inverter fed motors. The power sizes below do not comply with NEMA MG 1-1998 Part 30.2.2.8 for general purpose motors.
125–300 hp [90–200 kW] / 380–500 V
Cable
AC line
length
voltage
115 ft [30 m]
400 V
350–1075 hp [250–800 kW] / 380–500 V
Cable
AC line
length
voltage
115 ft [30 m]
500 V
115 ft [30 m]
500 V
115 ft [30 m]
400 V
115 ft [30 m]
400 V
1) With Danfoss du/dt filter
Rise time
[μsec]
0.368
0.536
0.680
0.712
Rise time
[μsec]
0.368
0.536
0.680
0.712
Rise time
[μsec]
0.256
0.328
0.456
0.960
Rise time
[μsec]
0.371
Rise time
[μsec]
0.371
Rise time
0.34 µsec.
Rise time
0.71 µsec.
0.80 µsec.
1)
0.61 µsec.
0.82 µsec.
1)
MG.33.BC.22 - VLT
®
is a registered Danfoss trademark
4 AutomationDrive FC 300 Selection
Upeak
du/dt
[kV]
[kV/μsec]
1.270
2.853
1.260
1.978
1.240
1.426
1.200
1.334
Upeak
du/dt
[kV]
[kV/μsec]
1.270
2.853
1.260
1.978
1.240
1.426
1.200
1.334
Upeak
du/dt
[kV]
[kV/μsec]
1.230
3.847
1.200
2.957
1.200
2.127
1.150
1.052
Upeak
du/dt
[kV]
[kV/μsec]
1.170
2.523
Upeak
du/dt
[kV]
[kV/μsec]
1.170
2.523
Peak
voltage
du/dt
1040 V
2447 V/µsec.
Peak
voltage
du/dt
1165 V
1389 V/µsec.
906 V
904 V/µsec.
942 V
1233 V/µsec.
760 V
743 V/µsec.
4
4-29