Danfoss FC 300 Design Manual page 62

Hide thumbs Also See for FC 300:
Table of Contents

Advertisement

4 AutomationDrive FC 300 Selection
Line Power Supply 3 x 200–240 V AC
AutomationDrive
FC 301/
AutomationDrive
FC 302
High/ Normal Load*
Typical Shaft Output
[kW]
Enclosure IP20
Enclosure IP21
Enclosure IP55, 66
Output current
Continuous
(3 x 200–240 V) [A]
4
Intermittent
(60 sec overload)
(3 x 200–240 V) [A]
Continuous
KVA (208 V AC) [KVA]
Max. input current
Continuous
(3 x 200–240 V) [A]
Intermittent
(60 sec overload)
(3 x 200–240 V) [A]
Max. cable size, IP20
[mm
Max. cable size, IP
21/55/66 [mm
2)
Max cable size with line
power disconnect
Max. electrical fuses [A]
1
Estimated power loss
at rated max. load [W]
Weight,
enclosure IP21, IP 55, 66
[kg]
Efficiency
* High overload = 160% torque during 60 s, Normal overload = 110% torque during 60 s
4-2
P15K
HO
NO
15
18.5
B4
C1
C1
59.4
74.8
89.1
82.3
21.4
26.9
54
68
81
74.8
35 (2)
2
2)
(AWG)]
2
(AWG)]
90 (3/0)
125
624
737
4)
45
4)
0.96
MG.33.BC.22 - VLT
P18K5
P22K
HO
NO
HO
NO
18.5
22
22
30
C3
C3
C1
C1
C1
C1
74.8
88
88
115
112
96.8
132
127
26.9
31.7
31.7
41.4
68
80
80
104
102
88
120
114
90 (3/0)
90 (3/0)
90 (3/0)
90 (3/0)
35 (2)
125
160
740
845
874
1140
45
45
0.97
0.97
®
is a registered Danfoss trademark
FC 300 Design Guide
P30K
P37K
HO
NO
HO
NO
30
37
37
45
C4
C4
C2
C2
C2
C2
115
143
143
170
173
157
215
187
41.4
51.5
51.5
61.2
104
130
130
154
156
143
195
169
120 (4/0)
120 (4/0)
120 (4/0)
120 (4/0)
70 (3/0)
150 (MCM 300)
200
250
1143
1353
1400
1636
65
65
0.97
0.97

Advertisement