Diagnostics
3.1 Diagnostics via LEDs
3.1.3.9

DRIVE-CLiQ Hub Module DMC20

Table 3- 49
Description of the LEDs on the DRIVE-CLiQ Hub Module DMC20
LED
Color
READY
-
Green
Orange
Red
Green/
red
Green/
orange
or
Red/
orange
198
Status
Off
Electronics power supply is missing or outside permissible
tolerance range.
Continuous
The component is ready for operation and cyclic DRIVE-
light
CLiQ communication is taking place.
Continuous
DRIVE-CLiQ communication is being established.
light
Continuous
At least one fault is present in this component.
light
Note:
The LED is activated regardless of whether the
corresponding messages have been reconfigured.
Flashing
Firmware is being downloaded.
light 0.5 Hz
Flashing
Firmware download is complete. Wait for POWER ON
light 2 Hz
Flashing
Component recognition via LED is activated (p0154).
light
Note:
Both options depend on the LED status when component
recognition is activated via p0154 = 1.
Description, cause
Commissioning Manual, (IH1), 01/2011, 6SL3097-4AF00-0BP1
Remedy
Remedy and
acknowledge fault
Carry out a POWER
ON