5.4 Encoder

The encoders may only be connected to the inverter when an EXP-...-ADV op-
tional card is installed.
For further details of the technical specifications, refer to the EXP-...-ADV optional
card manual.
For instructions regarding fastening of the optional card, see paragraph
lation of optional cards", page 150
Optional Card
EXP-DE-I1R1F2-ADV
EXP-DE-I2R1F2-ADV
EXP-SE-I1R1F2-ADV
EXP-SESC-I1R1F2-ADV
EXP-EN/SSI-I1R1F2-ADV
EXP-HIP-I1R1F2-ADV
EXP-ASC-I1R1F2-ADV
(*) Enc X = name assigned to the card by the software, see SECTION 530 - 532 - 534.

5.5 Serial interface (XS connector)

The ADV200 drive is equipped as standard with a port (9-pin D-SUB receptacle
connector: XS) for connection of the RS485 serial line used for drive/PC point-
to-point communication (through the GF-eXpress configuration software) or for
multi-drop connection.
To access the connector, remove the lower cover as illustrated in shown in
graph

5.5.1 Drive / RS 485 Port (not insulated) point-to-point connection

The connection indicated is without galvanic insulation !
Le raccordement indiqué n'a pas d'isolation galvanique !
Caution
Code
Encoder
S5L30 Incremental Digital Encoder (DE)
S5L35 Double Incremental Digital Encoder (2 x DE)
S5L31 Incremental Sinusoidal Encoder (SE)
S5L32 Incremental Sinusoidal Encoder + SinCos Absolute (SESC)
S5L33 Incremental Sinusoidal Encoder + Endat Absolute + SSI (SE-EnDat/SSI)
S5L34 Incremental Sinusoidal Encoder + Hiperface Absolute (SE-Hiperface)
S5LXX Incremental SinCos Absolute Encoder
5.2.1.
ADV200 • Quick start up guide - Specification and installation
of this manual.
PIN 1
PIN 2
PIN 3
PIN 4
Equipotentiality (optional)
PIN 5
0V (Ground for 5 V)
XS
PIN 6
PIN 7
PIN 8
PIN 9
PAR 530 - 532 - 534
Slot X card type (*)
Enc 1
Enc 7
Enc 2
Enc 3
Enc 4
Enc 5
Enc 8
Function
I/O
Electr. interface
Internal use
Internal use
RxA/TxA
I/O
RS485
Power supply
+5 V
Power supply
RxB/TxB
I/O
RS 485
Internal use
Internal use
I = Input
O = Output