Emerson Micro Motion 5700 Installation Manual page 18

Intrinsically safe outputs. all installation types (integral, 4-wire, and 9-wire)
Hide thumbs Also See for Micro Motion 5700:
Table of Contents

Advertisement

Mounting and sensor wiring
May 2019
2. Gently lift the transmitter straight up, and rotate the transmitter to the desired
3. Gently lower the transmitter onto the base, confirming that the transmitter is in a
4. Replace the clamp in its original position and tighten the cap screw. Torque to 28 in
18
Figure 3-9: Removal of the sensor clamp
position.
You can rotate the transmitter to any of the eight positions, but a stop exists that
will not allow a full 360° rotation.
Figure 3-10: Rotation of the transmitter head
locked position.
lbf (3.16 N m) to 30 in lbf (3.39 N m).