RD RDC6445GZ User Manual page 54

Table of Contents

Advertisement

Shenzhen Reader Technology Co., Ltd
pre-generate PWM, then set the Pre-generation Frequency and the
Pre-generation pulse scale.
Water Protector Enabled:
detect the input port of water protector. If this port is of low level, it will be deemed normal;
if this port is of high level, the mainboard will forcibly close the laser to suspend the work
in progress and the system will warn. If the water protector is not enabled, the mainboard
will not detect the input port of water protector and so the water protector can be
unconnected.
Laser PWM Frequency is used to set the pulse frequency of control signal used
by this laser, in general, glass tube is about 20KHZ, RF laser is about 5KHZ; the
maximum/minimum power (%) is used to set the limit power of this laser, that is to say,
during the operation, the maximum power set by the user can't be higher than that set
here and the minimum power set by the user can't be less than that set here, either.
When a laser's power is attenuated, then the laser attenuation quotiety may be set
If it is only provided with the single laser, it can show the one-path
parameter.
Prompt
(3)Other manufacturer parameters
Machine configuration
Machine Type: In most cases, the general engraving machine should be
selected and other types used for specific purposes.
Transmission Mode: generally the "Belt Stepping Type" should be made choice
of. The control algorithm will be changed a little when other types are selected.
Feeding Mode: it has single-way mode and two-way mode for option. If it is of
single-way feeding, it is unnecessary to check the coordinates. Feeding can be
conducted in the single-way mode; if it is of two-way feeding, the system will
check the maximum and minimum coordinates. The odd sequence means
feeding should be done to one direction and the even sequence means feeding
done to the other direction. The initial direction for the first time can be changed
through setting the directional polarity or modifying the plus and minus values of
the feeding length.
Power-Off-Restart Delay: it can be set to be 0~3000ms. After the power-off of
the electricity grid, the power supply of the system will not drop to 0 at once.
There is a delay during this time. The delay value set here should basically
consistent with the actual off-delay value. If the deviation of set value is larger,
on the de-energizing for continuous engraving, either the figure processed for
the second time is not closed with that before the cutoff, or it is coincided with
that too much.
When the water protector is enabled, the mainboard will
50

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents