PROGRAMMING

9.2.3 Program without using utility package

9 - 22
(1) Intelligent function module switch setting
Set the intelligent function module switches by clicking Switch setting on
<<I/O assignment>> of GX Developer.
For the program example, set intelligent function module switches as described
below.
Intelligent Function
Module Switch
Switch 1
No need to set (initial value (online))
1)
2)
Switch 2
3)
4)
Switch 3
Set the (upper half) of the IP address
Switch 4
Set the (lower half) of the IP address
Switch 5
No need to set
1: Set 0006
to start with the default basic parameters.
H
2: Set 0005
to start with the default MODBUS device assignment parameters.
H
3: Set 0004
to start with the default basic and MODBUS device assignment parameters.
H
Setting Details
Basic parameter starting method
Start with the user-set parameters (b0: 1)
MODBUS device assignment parameter starting method
Start with the user-set parameters (b1: 1)
Online change enable/disable setting
Online change enabled (b2: 1)
Send frame specification
Data are sent in Ethernet (V2.0)-compliant frame (b3: 0)
MELSEC-Q
Set Value
0007
H
( 1)
( 2)
( 3)
C001
H
0001
H
9 - 22