7
PARAMETER SETTING
Assignment Name
Coil assignment 1
Coil assignment 2
Coil assignment 3
Coil assignment 4
Coil assignment 5
Coil assignment 6
Coil assignment 7
Coil assignment 8
Coil assignment 9
Coil assignment 10
Coil assignment 11
Coil assignment 12
Coil assignment 13
Coil assignment 14
Coil assignment 15
Coil assignment 16
Input assignment 1
Input assignment 2 to 16
Input register assignment 1 to 16
Holding register assignment 1
Holding register assignment 2
Holding register assignment 3
Holding register assignment 4
Holding register assignment 5
Holding register assignment 6
Holding register assignment 7
Holding register assignment 8
Holding register assignment 9 to 16
7 - 30
[Set values of default assignment parameters]
Buffer Memory
Address
0900
to 0903
H
H
0904
to 0907
H
H
0908
to 090B
H
H
090C
to 090F
H
H
0910
to 0913
H
H
0914
to 0917
H
H
0918
to 091B
H
H
091C
to 091F
H
H
0920
to 0923
H
H
0924
to 0927
H
H
0928
to 092B
H
H
092C
to 092F
H
H
0930
to 0933
H
H
0934
to 0937
H
H
0938
to 093B
H
H
093C
to 093F
H
H
0940
to 0943
H
H
0944
to 097F
H
H
0980
to 09BF
H
H
09C0
to 09C3
H
H
09C4
to 09C7
H
H
09C8
to 09CB
H
H
09CC
to 09CF
H
H
09D0
to 09D3
H
H
09D4
to 09D7
H
H
09D8
to 09DB
H
H
09DC
to 09DF
H
H
09E0
to 09FF
H
H
*1: Use the following expression to find the set value of the head MODBUS device number.
Head MODBUS device number = Last 5 digits of MODBUS device number to be set - 1
POINT
The programmable controller CPU device range varies depending on the
programmable controller CPU.
(Refer to QCPU User's Manual (Function Explanation, Program Fundamentals))
Depending on the programmable controller CPU, some of the default assignment
parameter range may not be usable.
In such a case, observe either of the following not to access the devices outside the
allowable range.
Set the MODBUS device assignment parameters. (Refer to Section 7.4)
Make the setting within the allowable programmable controller CPU device
range.
Do not access any device outside the allowable range when using the default
assignment parameters.
Default Assignment Parameter Setting Items
Device code
Head device
(Device symbol)
number
009D
(Y)
H
0090
(M)
H
0091
(SM)
H
0092
(L)
H
00A0
(B)
H
0093
(F)
H
00A1
(SB)
H
0094
(V)
H
0098
(S)
H
00C0
(TC)
H
00C1
(TS)
H
00C6
(SC)
H
00C7
(SS)
H
00C3
(CC)
H
00C4
(CS)
H
0000
H
009C
(X)
H
0000
H
0000
H
00A8
(D)
H
00A9
(SD)
H
F000
H
00B4
(W)
H
00B5
(SW)
H
00C2
(TN)
H
00C8
(SN)
H
00C5
(CN)
H
0000
H
MELSEC-Q
Head MODBUS
device number (*1)
0000
0
H
0000
8192
H
0000
20480
H
0000
22528
H
0000
30720
H
0000
38912
H
0000
40960
H
0000
43008
H
0000
45056
H
0000
53248
H
0000
55296
H
0000
57344
H
0000
59392
H
0000
61440
H
0000
63488
H
0000
0
H
0000
0
H
0000
0
H
0000
0
H
0000
0
H
0000
20480
H
5000
22528
H
0000
30720
H
0000
40960
H
0000
53248
H
0000
57344
H
0000
61440
H
0000
0
H
Assignment
points
8192
8192
2048
8192
8192
2048
2048
2048
8192
2048
2048
2048
2048
2048
2048
0
8192
0
0
12288
2048
4096
8192
2048
2048
2048
2048
0
7 - 30