Mitsubishi Electric MELCEC Q Series User Manual page 222

A mode
Table of Contents

Advertisement

APPENDICES
Number
Name
SUM instruction
D9003
detection bits
*1
MINI link master
D9004
module error
*1
AC DOWN
D9005
counter
D9006
Battery low
*1
Shelf-diagnostic
D9008
error
Annunciator
D9009
detection
Table App.2.2 Special Register List (continued)
Description
The number of bits
• The number of bits detected by execution of the SUM
detected by SUM
instruction are stored in BIN code and updated every
instruction detection.
execution thereafter.
• Error status of the MINI (S3) link detected on loaded
MINI (S3) link module is stored.
b15
8 7 6 5 4 3 2 1
Error detection status
Data communication between
the programmable controller
CPU and MINI (S3) link module
is disabled.
• 1 is added each time input voltage becomes 85% or
AC DOWN count
less of rating while the CPU module is performing
operation, and the value is stored in BIN code.
• Bits which correspond to CPU of which battery is low
are turned on in D9006, as shown below.
B15
Indicates the CPU
0
module of which
battery voltage is low.
0: Normal
1: Battery low
Self-diagnostic error
• When error is found as a result of self-diagnosis, error
number
number is stored in BIN code.
• When one of F0 to 255 is turned on by OUT F or
SET F, the F number, which has been detected earliest
among the F numbers which have turned on, is stored
in BIN code.
• D9009 can be cleared by RST F or LEDR instruction. If
another F number has been detected, the clearing of
D9009 causes the next number to be stored in D9009.
F number at which
• When one of F0 to 255 is turned on by OUT F or
external failure has
SET F, the F number, which has been detected earliest
occurred
among the F numbers which have turned on, is stored
in BIN code.
• D9009 can be cleared by executing RST F or LEDR
instruction or moving INDICATOR RESET switch on
the CPU front to the ON position. If another F number
has been detected, the clearing of D9009 causes the
next number to be stored in D9009.
Details
to
b8 b7
8 7 6 5 4 3 2 1
Bits which correspond to the
signals of MINI (S3) link
module, shown below, are
turned on as the signals are
turned on.
Hardware error (X0/X20)
MINI (S3) link error detection
(X6/X26)
MINI (S3) link communication
error (X7/X27)
B3
B2
0
App - 28
Applicable CPU
Dedicated to
A0J2H.
to
b0
Usable with
AnA, A2AS,
AnA board and
AnU.
Usable with all
types of CPUs.
B1
B0
Dedicated to
A3V.
CPU A
CPU B
CPU C
Usable with all
types of CPUs.
Unusable with
A3, A3N, A3A,
A73 and A3N
board.
Usable with A3,
A3N, A3A, A73
and A3N board.