Mitsubishi Electric MELCEC Q Series User Manual page 216

A mode
Table of Contents

Advertisement

APPENDICES
Number
Name
Registration
area busy signal
M9081
for
communication
request
Final station
M9082
number
disagreement
*2
Error check
M9084
BASIC program
M9086
RUN flag
BASIC program
M9087
PAUSE flag
Power supply
M9090
problem status
on the PC side
*1
Operation error
M9091
detail flag
Microcomputer
*1
subroutine call
M9091
error flag
External power
M9092
supply problem
status
Duplex power
M9092
supply overheat
error
Duplex power
M9093
supply error
Table App.2.1 Special Relay List (continued)
Description
OFF:Communication
request to remote
terminal modules
• Indication of communication enable/disable to
enabled
remote terminal modules connected to the MINI
ON: Communication
(S3) link module, A2C or A52G.
request to remote
terminal modules
disabled
• Turned on when the final station number of the
OFF:Final station
remote terminal modules and remote I/O modules
number agreement
connected to the A2C or A52G disagrees with the
ON: Final station
total number of stations set in the initial setting.
number
• Turned off when the final station number agrees
disagreement
with the total number of stations at STOP
• Specify whether the following errors are to be
checked or not after the END instruction is
executed (to set END instruction processing
OFF:Checks enabled
time):
ON: Checks disabled
• Fuse blown
• I/O module verify error
• Battery error
OFF:A3M-BASIC stop
• Turned on when the A3M-BASIC is in RUN state,
ON: A3M-BASIC run
and turned off when it is in STOP state.
OFF:A3M-BASIC RUN
• Specifies enable/disable of A3M-BASIC execution
enable
when the A3MCPU is in PAUSE state.
ON: A3M-BASIC
OFF: A3M-BASIC is executed.
disable
ON:
• Turns on if the power to the personal computer
OFF:Normal
side is shut off when the external power supply is
ON: Power off
connected to the CPU board.
It stays on even after the status becomes normal.
• Turned on when an operation error detail factor is
OFF:No error
stored at D9091, and remains on after normal state
ON: Error
is restored.
• Turned on when an error occurred at execution of
OFF:No error
the microcomputer program package, and remains
ON: Error
on after normal state is restored.
• Turns on when the external power being supplied
OFF:Normal
to the CPU board is shut off.
ON: Power off
It stays on even after the status becomes normal.
OFF:Normal
• Turned on when overheat of a duplex power
ON: Overheat
supply module is detected.
OFF:Normal
ON: Failure or AC
• Turned on when a duplex power supply module
power supply
caused failure or the AC power supply is cut down.
down
Details
A3M-BASIC is not executed.
App - 22
Applicable CPU
Usable with AnA,
AnA, AnU, A2AS,
QCPU-A
(A Mode)
A2C and A52G.
Dedicated to A2C
and A52G.
RUN
Unusable with An,
A2C and A3V.
Dedicated to A3M
Dedicated to
A3M.
Dedicated to
A2USH board
Usable with AnA,
A2AS, AnU and
QCPU-A
(A Mode).
Unusable with
AnA, A2AS, AnU
and QCPU-A
(A Mode).
Dedicated to
A2USH board
Dedicated to A3V.
Dedicated to A3V.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qcpu-a seriesQ02cpu-aQ02hcpu-aQ06hcpu-a