HEATSEEKER FLUE TERMINATION (COWLS) REGULATIONS
Natural Draught
Refer to Note 1
AREA
A:
Horizontally from a neighboring structure. ......................................................1000mm
B:
If less than a meter horizontally from a neighboring structure
then terminates above that structure by. ...........................................................500mm
C:
From any opening into a building. ...................................................................1500mm
D:
From another flue terminal. ...............................................................................200mm
Notes:
1.
A trafficable roof designed for personal or public use, the end of the flue shall be at least
2 meters above the roof level. This dimension is to be increased where necessary so that
the minimum distance of 500mm is maintained above any surrounding parapet or at least
200mm from the nearest part of a chimney.
2.
The current version of the AG601 gas codes and any other relevant codes should be
read in conjunction with the above guidelines to ensure a correct and safe installation.
D
B
A OR B
C
Refer to Note 1
600mm
CLEARANCE REQUIRED
47