Dmx-512 Control Connection; Dmx-512 Connection With Dmx Terminator - Terbly TP02-CW User Manual

Led tv panel light
Table of Contents

Advertisement

6. DMX-512 CONTROL CONNECTION

Connect the provided male side of the XLR cable to the female XLR output of your controller
and the female side of the XLR cable to the male XLR input of the device. You can connect
multiple devices together in a serial fashion. The cable needed should be two core, screened cable
with XLR input and output connectors. Please refer to the diagram below.
Address 3
Address 2
Address 1
Please note: to ensure maximal stability, when the input voltage is 100~120V, only two devices
may be connected together in this manner! From the thirdly devices, please connect to power
supply to get power for the second link; when the input voltage is 220~240V, only four devices
may be connected together in this manner! From the fifthly devices, please connect to power
supply to get power for the second link

7. DMX-512 CONNECTION WITH DMX TERMINATOR

For installations where the DMX cable has to run over a long distance or is in an electrically
noisy environment, such as in a discotheque, it is recommended to use a DMX terminator. This
helps in preventing corruption of the digital control signal caused by electrical noise. The DMX
terminator is an XLR plug with a 120 Ω resistor connected between pins 2 and 3,which is then
plugged into the output (female) XLR socket of the last fixture in the chain. Please see
illustrations below.
TP02-CW,WW User Manual
10
XM1268/1257-V1.0-NR

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tp02-ww

Table of Contents