Thank you for your patronage. We are confident that our excellent products and service can satisfy you. For your own safety, please read this user manual carefully before installing the device. In order to install , operate, and maintain the lighting safety and correctly. We suggest that the installation and operation should be done by the verified technician and follow the instruction strictly.
replacement of the cable must be done by an authorized dealer. Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the power cord by the plug. Never pull out the plug by tugging the power cord. During initial start-up some smoke or smell may arise.
If this device will be operated in any way different to the one described in this manual, the product may suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to short-circuit, burns, electric shock, lamp explosion, crash, etc. 4.
Page 7
Installation via the Omega holders Fixed the clamp on the bracket by tighten up the M12 screw on the bracket to the 13 hole in the middle of the bracket. Pass the safety rope through the connecting hole under the side panel, hanging on the fixed bracket or other fixed station, and can also be floor-mounted(or on any other flat surface) without fixing, remaining steady no matter what the angle of the head.
Page 9
Layout Drawings: Mounting points Be sure this fixture is kept at least 0.5m away from any flammable materials (decoration etc.). Always use and install the supplied safety cable as a safety measure to prevent accidental damage and/or injury in the event the clamp fails. Overhead mounting requires extensive experience, including amongst others calculating working load limits, a fine knowledge of the installation material being used, and periodic safety inspection of all installation material and the fixture.
5. DMX-512 control connection Connect the provided XLR cable to the female 5-pin XLR output of your controller and the other side to the male 5-pin XLR input of the LED PROFILE. You can chain multiple LED PROFILE together through serial linking. The cable needed should be two core, screened cable with XLR input and output connectors.
the DMX controller. The allocation of this starting address is achieved by setting the correct number on the display located on the base of the device. You can set the same starting address for all fixtures or a group of fixtures, or make different address for each fixture individually.
8.1.3 SetSlave With this function, you can define the device as slave. 1. Access the main menu. 2. Tap the <Up/Down>button until“SetSlave”is displayed. 3. Press ENTER, the display will show“SetSlave”. 4. Tap the <Up/Down>button the display will show “Slave1”, ”Slave2”, ”Slave3”. 5.
TimePass With this function, you can display the timer password. 1. Access the main menu. 2. Press <Up/Down>, the display will show “ ”. TimePass ”. The time password is 038. 3. Press< ENTER>, the display will show“ TimePass 4. Press <ENTER> to confirm or press <MODE/ESC> to return to the main menu. Clr Last With this function, you can clear last run time of the fixture.
2. Press <Up/Down>, the display will show “NoDMXSta”. 3. Press< ENTER>, the display will show“NoDMXSta”. 4. The display show “Hold”,Press <Up/Down>, the display will show “CloShut”, “Auto”. 5. Press <ENTER> to confirm or press <MODE/ESC> to return to the main menu. 8.3.2 Service setting Password——The Password for this function is “50”.
8.3.5 Refresh 1 Access the main menu. ”. 2 Press <Up/Down>, the display will show“ Refresh ”. 3 Press< ENTER>, the display will show“ Refresh 4 The display show“1200” ,Press <Up/Down>, the display will show“900~1200~1500” , “2.5K”,“4K”,“5K”,“10K”,“15K”,“20K”,“25K”. 5 Press <ENTER> to confirm or press <MODE/ESC> to return to the main menu. 8.3.6 Gamma 1 Access the main menu.
1 Access the main menu. 2 Press <Up/Down>, the display will show “ ”. UserMode 3 Press< ENTER>, the display will show “ ”. UserMode 4 The display show “5CH” ,Press <Up/Down>, the display will show “6CH”, “8CH”, “13CH”, “19CH”. 5 Press <ENTER>...
Page 18
BLUE LED FINE : 0-255 BLUE FINE Adjustment MINT LED 0-255 MINT ( 0-Black , 255-100% Mint ) MINT LED FINE : 0-255 MINT FINE Adjustment AMBER LED 0-255 AMBER ( 0-Black , 255-100% Amber ) AMBER LED FINE : 0-255 AMBER FINE Adjustment COLOR TEMPERATURE :...
Page 19
224-231 Color Macro 29 232-239 Color Macro 30 240-247 Color Macro 31 248-255 Color Macro 32 INTERNAL PROGRAM MACROS : NO FUNCTION 1-30 Internal Program 01 31-60 Internal Program 02 61-90 Internal Program 03 91-120 Internal Program 04 121-150 Internal Program 05 151-180 Internal Program 06 181-210...
10. Options 11. CLEANING AND MAINTENANCE The following points have to be considered during the inspection: 1) All screws for installing the devices or parts of the device have to be tightly connected and must not be corroded. 2) There must not be any deformations on the housing, color lenses, fixations and installation spots (ceiling, suspension, trussing).
12.TECHNICAL SPECIFICATIONS Power supply: AC 100-240V~, 50/60Hz Power consumption: 200W Packing dimensions: 56.5 x 38.5 x 33.5 cm Net weight: 7.2 KG Gross weight:11.5KG Remark : errors and omissions for every information given in this manual excepted. All information is subject to change without prior notice. XM1193-V1.0 -E...