6. DMX-512 CONTROL CONNECTION

Connect the provided male side of the XLR cable to the female XLR output of your controller
and the female side of the XLR cable to the male XLR input of the device. You can connect
multiple devices together in a serial fashion. The cable needed should be two core, screened cable
with XLR input and output connectors. Please refer to the diagram below.
Address 1
Address 7
Address 13
Please note: to ensure maximal stability, when the voltage is 100V~120V, only two devices may
be connected together in this manner! From the third device, please connect to power supply to
get power for the second link; when the voltage is over 200V~240V, only four devices may be
connected together in this manner! From the fifthly device, please connect to power supply to get
power for the second link.

7. DMX-512 CONNECTION WITH DMX TERMINATOR

For installations where the DMX cable has to run over a long distance or is in an electrically
noisy environment, such as in a discotheque, it is recommended to use a DMX terminator. This
helps in preventing corruption of the digital control signal caused by electrical noise. The DMX
terminator is an XLR plug with a 120
resistor connected between pins 2 and 3,which is then
plugged into the output (female) XLR socket of the last fixture in the chain. Please see
illustrations below.