  • Page 1 LED COLOR CHANGER USER MANUAL T90H-WW IP KEEP THIS MANUAL FOR FUTURE NEEDS...
  • Page 2: Table Of Contents

    Thank you for purchasing a TERBLY product. You have acquired a powerful and versatile fixture. We are confident that you will be satisfied with our excellent products and service. For your own safety, please read this user manual carefully before installing and operating the device.
  • Page 3: Safety Instructions

    Make sure that the available voltage is not higher than that which is stated at the end of this manual. Make sure the power cord is never crushed or damaged by sharp edges.If this should be T90H-WW IP User Manual XM1307-V1.0-A...
  • Page 4 If this device is operated in any way different to the ones described in this manual the product may suffer damage and the warranty becomes void.Furthermore any other operation may lead to short-circuits burns electric shocks etc. T90H-WW IP User Manual XM1307-V1.0-A...
  • Page 5: Features

    Strobe effect with 1-25 flashes per second and pulse effect Dimmer 0%~100% full range dimming DISPLAY Friendly blue and white LCD display SOFTWARE Upgrades fast and convenient through DMX cable with DMX-512 controller OTHER SPEC IP Rating: IP 65 WEIGHT Net weight: 8.9 kg T90H-WW IP User Manual XM1307-V1.0-A...
  • Page 6 PHOTOMETRIC DATA DMX CHANNEL CHART T90H-WW IP User Manual XM1307-V1.0-A...
  • Page 7: Fixture Overview

    PowerCON TRUE1 OUT Up-button 5 pin DMX OUT Down-button Mounting Yoke Mode/Esc-button Adjustable Handle LCD Menu Control Display BLADE SHUTTERS ENTER-button ROTATION 5pin DMX IN Gobo Slot (Gobo and Holder not included) PowerCON TRUE1 IN T90H-WW IP User Manual XM1307-V1.0-A...
  • Page 8: Dimensional Drawings

    4. DIMENSIONAL DRAWINGS T90H-WW IP User Manual XM1307-V1.0-A...
  • Page 9: Installation Instructions

    If you lack these qualifications do not attempt the installation yourself. Improper installation can result in bodily injury. T90H-WW IP User Manual XM1307-V1.0-A...
  • Page 10 Pull the safety cable through the holes on the bottom of the base and over the trussing system or another suitable rigging point. Insert the end into the carabiner and tighten the safety screw. Important This step is very important to ensure safe rigging of the fixture. T90H-WW IP User Manual XM1307-V1.0-A...
  • Page 11 T90H-WW IP User Manual XM1307-V1.0-A...
  • Page 12: Dmx-512 Control Connection

    XLR plug with a 120 resistor connected between pins 2 and 3 which is then plugged into the output (female) XLR socket of the last fixture in the chain.Please see illustrations below. T90H-WW IP User Manual XM1307-V1.0-A...
  • Page 13: Device Dmx Start Address Selection

    1 minute then the display will switch off automatically.The Display does not need external power to operate.Hold down the -button for 10 seconds and the Display will turn on by using the unit’s battery built in battery. Default settings shaded T90H-WW IP User Manual XM1307-V1.0-A...
  • Page 14 Reset gobos Gobos Auto… Auto =XXX ManCntrl Fine adjustment of the lamp DimMode… DimM=XXX password Password “050” Calibrate and adjust the Calibrat effects standard/right White White =xxx position UserMode UserMode Mode A Mode B Mode C T90H-WW IP User Manual XM1307-V1.0-A...
  • Page 15 4. Tap the <Up/Down> button choose each channel. 5. Press ENTER to confirm or press <MODE/ESC> to return to the main menu. 9.1.3. Set Slave With this function, you can define the device as slave. 1. Access the main menu. T90H-WW IP User Manual XM1307-V1.0-A...
  • Page 16 4. The display will show“XXXX”(Hours). 5. Press <ENTER> to confirm or press <MODE/ESC> to return to the main menu. Last Hrs With this function you can display last the running time of the device.The display shows T90H-WW IP User Manual XM1307-V1.0-A...
  • Page 17 “Info” is displayed. Press ENTER the display will show “Info” .Tap the<Up/Down> button until“Temp Info”is displayed. Press ENTER the display will show“Temp Info”. 2. Press <Up/Down> the display will show“Head Temp”. 3. Press< ENTER> the display will show“Head Temp”. 4. The display show“XXX °C/ °F”. T90H-WW IP User Manual XM1307-V1.0-A...
  • Page 18 With this function when the drive is not DMX signal it runs automatism close hold and music the default is hold. 1. Tap <MODE/ESC> button access the main menu Tap the <Up/Down> button until “Personal”is displayed.Press ENTER the display will show“Personal”.Tap the T90H-WW IP User Manual XM1307-V1.0-A...
  • Page 19 2 Press <Up/Down> the display will show“Off Time”. 3 Press< ENTER> the display will show“Off Time”. 4 The display show“05m Press <Up/Down> the display will show“02~60m”. 5 Press <ENTER> to confirm or press <MODE/ESC> to return to the main menu. Key Lock T90H-WW IP User Manual XM1307-V1.0-A...
  • Page 20 1. Tap <MODE/ESC> button access the main menu Tap the <Up/Down> button until “Personal”is displayed.Press ENTER the display will show“Personal”. 2. Press <Up/Down> the display will show“FastHold”. 3. Press< ENTER> the display will show“FastHold”. 4. The display show“OFF Press <Up/Down> the display will show“ON”. T90H-WW IP User Manual XM1307-V1.0-A...
  • Page 21 3 Press< ENTER> the display will show“Calibrat”. 4 The display show“White=XXX”. 5 Press <ENTER> to confirm or press <MODE/ESC> to return to the main menu. 9.7. MODE SET 9.7.1. User Mode With this function you can create user defined channel orders. T90H-WW IP User Manual XM1307-V1.0-A...
  • Page 22 1 If the slave fixture chooses Run For Slave 1 from the menu of 1-3,then it will receive the part 1’s automatic program from link in the same way when the slave fixture T90H-WW IP User Manual XM1307-V1.0-A...
  • Page 23: Dmx Protocol

    DMX channel´s functions and their values (8 DMX channels): Mode/Channel Value Function White LED 1 : 0-255 White ( 0-Black , 255-100% White ) White LED Fine 1 : Fine control for White adjustment 0-255 Rotating gobo index T90H-WW IP User Manual XM1307-V1.0-A...
  • Page 24 120-139 Internal program 2(secne9~16 of EEPROM) 140-159 Internal program 3(secne17~24 of EEPROM) 160-179 Internal program 4(secne25~32 of EEPROM) 180-199 Internal program 5(secne33~40 of EEPROM) 200-219 Internal program 6(secne41~48 of EEPROM) 220-239 Internal program 7(secne49~56 of EEPROM) 240-255 No function T90H-WW IP User Manual XM1307-V1.0-A...
  • Page 25: Cleaning And Maintenance

    Please refer to the instructions under“Installation instructions”. Should you need any spare parts please order genuine parts from your local dealer. 12. SERVICE For all service needs please contact your local authorized dealer or Terbly directly. Our contact details are: Email: QA@terbly.com...