Proof Test Procedure Kfd0-Sd2-(Ex) - Pepperl+Fuchs SIL KFD0-SD2-*. Series Safety Manual

Solenoid driver
Table of Contents

Advertisement

SAFETY MANUAL SIL K*D0-SD*-(EX)*.****(.SP), HIC2871
Proof Test
4.1.1

Proof Test Procedure KFD0-SD2-(Ex)*.*****

Connect the module specific load resistor between the terminals 1+ and 2-
(and terminals 4+ and 5- for 2-channel device).
Connect the power supply set at nominal 20 V DC between terminals 7 and 8.
Measure the output voltage via multimeter. Compare the resulting value to
the nominal value specified in the table below.
Short circuit the load resistor and measure the short circuit current via
multimeter. Compare the resulting value to the nominal value specified in the
table below.
If applicable, repeat the test procedure for output II by connecting the power
supply between the terminals 9 and 8 instead of 7 and 8 and the repetition of
the output voltage and short circuit test.
Module
KFD0-SD2-(Ex)1.1180
KFD0-SD2-(Ex)2.1045
KFD0-SD2-(Ex)1.1065
KFD0-SD2-(Ex)1.10100
KFD0-SD2-(Ex)1.1045
KFD0-SD2-(Ex)2.1245
Table 4.1
I
SC
II
SC
Figure 4.1
Usage in Zone 0, 1, 2/Div. 1, 2 only for KFD0-SD2-Ex*.*****.
Multimeter
Multimeter
(mA)
(V)
1+
R
load
2-
3-
4+
R
load
5-
6-
Zone 0, 1, 2
Div. 1, 2
Proof test set-up for KFD0-SD2-(Ex)*.*****
Output resistor
Output voltage
(Ω)
(V)
150
> 11
270
> 10
180
> 10
100
> 9.5
270
> 10
270
> 12
KFD0-SD2-Ex2.1245
7
8 (+/-)
9
Short circuit
current (mA)
80 < I
< 90
sc
45 < I
< 50
sc
65 < I
< 75
sc
95 < I
< 105
sc
45 < I
< 50
sc
45 < I
< 50
sc
I
V
II
Zone 2
Div. 2
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents