Taylor C606 Operator's Manual page 45

Combination freezer
Table of Contents

Advertisement

Menu Options
Touch the AUTO symbol
symbol
to move up or down through the Menu.
Select a Menu option by aligning the option with the
arrow on the left side of the screen, then touch the
CALIBRATION symbol
by selecting EXIT FROM MENU or touch the CONE
symbol
.
The following menu options are listed in the
Manager's Menu.
EXIT FROM MENU
SYRUP CALIBRATION
VERIFY CALIBRATION
SERVINGS COUNTER
SET CLOCK
AUTO HEAT TIME
AUTO START TIME
STANDBY MODE
BRUSH CLEAN CYCLE
MIX LEVEL AUDIBLE
FAULT DESCRIPTION
LOCKOUT HISTORY
FAULT HISTORY
HEAT CYCLE SUMMARY
HEAT CYCLE DATA
SYSTEM INFORMATION
CURRENT CONDITIONS
Selecting "EXIT FROM MENU" will exit the
Manager's Menu and return the control panel
symbols to normal operation.
Model C606
or OPTIONAL FLAVOR
. Exit the Menu program
The SYRUP CALIBRATION option allows the
manager to access the calibration screen selections
from the Manager's Menu. The same functions
found in the calibration menu are displayed on the
screen when this menu option is selected.
(See "SYRUP SYSTEM" on page 78.)
UNFLAVORED DRAW
SYRUP CALIBRATION
SYRUP PRIME
>
EXIT
Note: The unflavored draw option will only appear
on the screen when the shake side is in the AUTO
mode.
The VERIFY CALIBRATION option is used to verify
the amount of syrup dispensed is within the proper
specification. (See Figure 48)
VERIFY CALIBRATION
Select a Flavor
< Press to Clear
Remove the syrup valve from the dispensing door.
With the line fully primed with syrup, position the
syrup valve over the small chamber side of the
divided syrup cup, then select the corresponding
favor selection. Syrup will flow into the cup and
automatically stop. Place the cup on a flat surface
and check the amount of syrup dispensed. If the
level is not within the correct specification, the flavor
will need to be recalibrated.
(See SYRUP CALIBRATION on page 78.)
It is recommended to verify the calibration of each
syrup flavor and note any flavors that need to be
recalibrated before exiting the Manager's Menu to
access the CALIBRATION Menu.
Select the CALIBRATION symbol
VERIFY CALIBRATION screen and return to the
Manager's Menu list.
39
Figure 47
Figure 48
to exit the
120515