Mitsubishi Melsec-L Series User Manual page 373

Communication module
Hide thumbs Also See for Melsec-L Series:
Table of Contents

Advertisement

Item
Fixed number of
data/Variable number
Fixed number of data
of data
Number of data
1
Start address of data
D0
storage area
Conversion unit
Word
Conversion
HEX ASCII decimal
Number of digits
5
Blank-padded
0
character
Sign
Unsigned
Sign character
- (Not settable)
Number of decimals
No decimal point
Delimiter
No delimiter
1
Header 00837 Terminator
Send data
Item
Fixed number of
data/Variable number
Fixed number of data
of data
Number of data
1
Start address of data
D0
storage area
Conversion unit
Double word
Conversion
HEX ASCII decimal
Number of digits
10
Blank-padded
0
character
Sign
Signed
Sign character
+
Number of decimals
8
Delimiter
No delimiter
Header +00.01180485
1
Send data
Terminator
1: "_" indicates a blank.
App. - 44
(2) Data example
The following table shows send data when a packet consists
of Header Conversion variable Terminator and data stored in the data
storage area is D0=837 (0345
(Reference: 120345
), D1=18 (0012
H
=1180485 in decimal form)
H
Setting Details
Fixed number of data
1
D0
Word
HEX ASCII decimal
5
Space
Signed
+
2
Comma
Header +_ _ 8.37, Terminator
Setting Details
Fixed number of data
2
D0
Word
HEX ASCII decimal
5
Space
Unsigned
- (Not settable)
No decimal point
No delimiter
Header _ _ 837 _ _ _18
Terminator
).
H
Fixed number of data
1
D0
Word
HEX ASCII decimal
Variable number of digits
- (Not settable)
Signed
+
No decimal point
Comma
Header +837, Terminator
Fixed number of data
2
D0
Word
HEX ASCII decimal
5
0
Signed
+
2
Comma
Header +008.37, +000.18
Terminator