5. Diagnosis
5.
Diagnosis
5.1
Network status LED
The network status LED shows the communication status.
LED is
Status
Off
No bus communication
green
Bus communication active
Tab. 5.1: Status LED
5.2
PROFIBUS error codes
The following faults can occur if the PROFIBUS module is used: A complete list can be
found in the System Manual for the controller.
Fault message
Meaning of fault message
Main
Sub-
index
index
22
0
PROFIBUS:
faulty initialization
1
PROFIBUS: reserved
2
PROFIBUS communication
fault
3
PROFIBUS:
invalid slave address
4
PROFIBUS:
fault in value range
Tab. 5.2: PROFIBUS error codes
The following faults concern FHPP, but can also occur if the PROFIBUS module is used:
Please refer to the FHPP manual for detailed information.
30
Shows:
No communication via PROFIBUS.
Measure
Technology module defective?
Please contact technical support.
Check set slave address
Check bus connection
Check cables
Communication has been started with slave address 126.
Select a different slave address.
Mathematical fault in the calculation of the physical units.
Value range of the data and the physical units are not
suited together. Contact technical support
Festo P.BE-CMMS-FHPP-PB-SW-EN en 0708NH