Item
Differential points
Master control relay points (MCR)
No. of labels (JP and LOOP)
No. of step laddars
No. of subroutines
Pulse catch input
No. of interrupt programs
Self-diagnosis function
Calendar timer
Backup by F12, P13
Flash ROM
instructions
Note4)
backup
Automatic backup
when power is cut off
Battery backup
Potentiometer (Volume) input
Thermister input
Bettery life
Comment storage
PLC link function
Other functions
Note1)The number of points actually available for use is determined by the hardware configuration.
Note2)The number of points can be increased by using an auxiliary timer.
Note3)Precision of calendar timer:
- At 0°C: less than 119 seconds per month
- At 25°C: less than 51 seconds per month
- At 55°C: less than 148 seconds per month
Note4)Writing is available up to 10000 times. When the optional battery is used, all rea can be backed
up. Areas to be held and not held can be specified using the system registers.
Note5)If an area is held when the battery is not installed, the value of data may be indefinite as it is not
cleared to 0 when the power is turned on. When the battery ran out of the power, the data at the
hold area will be indefinite.
10-8
C32T
C32T2
C32TTM
C32T2TM
Unlimited points
256 points
256 points
1000 stages
500 subroutines
8 points (X0, X1, X3, X4:5µs X2, X5 to X7: 100µs)
9 programs (external input 8 points X0, X1, X3, X4: 5µs X2, X5 to
X7: 100µs), periodical interrupt 1 point (0.5ms to 30s)
Such as watchdog, program syntax check
Available (year, month, day, hour, minute, second and day of
week) (However, this can only be used when a battery has been
Note3)
installed.)
Data register (32765 words)
Counter 16 points (1008 to 1023), internal relay 128 points (R2480
to R255F), data register 55 words (32710 to 32764)
Memory that is set as hold area at system register (However, only
when an optional battery has been installed.)
2 points, Resolution: 10 bits (K0 to K1000) (C32TH, C32T2H,
C24R2H, C28P2H only)
2 points, Resolution: 10 bits (K0 to K1000) (C32THTM,
C32T2HTM, C24R2HTM, C28P2HTM only)
220 days or more (Actual usage value: approx. 840 days (25°C))
(Periodic replacement interval: 1 year) (Value applies when no
power is supplied at all)
All kindls of comments, including I/O comments, remarks and block
comments can be sotred. (328kbyte)
Max. 16 units, Link relay: 1024 points, Link register: 128 words
(Link area allocation can be switched between the first half and the
second half.)
Program edition during RUN, constant scan, forced on/off,
password, floating-point operation, and PID processing
Descriptions
C24R2
C24R2TM
Note5)
C28P2
C28P2TM