Sample program
Continuous interpolation control (linear and circular)
• Using linear and circular interpolation functions, perform positioning control that draws trajectory like
the one shown below.
• The interval between the first postion P1 and P2 and the interval between P3 and P4 perform control
using linear interpolation.
• The interval between P2 and P3 performs circular interpolation control using center designation.
• The interval between P4 and P1 performs circular interpolation control using passing position
designation.
I/O Allocation
I/O No.
Description
XB
Positioning start
XC
Emergency stop switch
R20
From P1 to P2 start
R21
From P2 to P3 start
R22
From P3 to P4 start
R23
From P4 to P1 start
R2F
Positioning done
6-52
I/O No.
Description
R9010
Always ON
R903A
Control flag (CH0)
R903C
Control flag (CH2)
R904E
Circular interpolation control flag