Troubleshooting

8.3 Warnings and Alarms

NOTICE
Refer to the operating guide for an overview of warning and alarm types, and for the full list of warnings and alarms.
Alarm word, warning word, and PROFIBUS warning word are shown on the frequency converter display in hex format. When
there is more than 1 warning or alarm, the sum of all warnings or alarms is shown. Alarm word, warning word, and
PROFIBUS warning word can also be shown using the fieldbus in parameter 16-90 Alarm Word, parameter 16-92 Warning
Word, and parameter 9-53 Profibus Warning Word.
Unit
Alarm word
Bit (hex)
diagnoses
(parameter 16-90 Alarm
bit
Word)
00000001
48
Brake check
Power card overtem-
00000002
49
perature
00000004
50
Ground fault
Control card overtem-
00000008
51
perature
00000010
52
Control word timeout
00000020
53
Overcurrent
00000040
54
Torque limit
Motor thermistor overtem-
00000080
55
perature
Motor ETR overtem-
00000100
40
perature
00000200
41
Inverter overloaded
00000400
42
DC-link undervoltage
00000800
43
DC-link overvoltage
00001000
44
Short circuit
00004000
46
Mains phase loss
00008000
47
AMA not OK
00010000
32
Live zero error
00020000
33
Internal fault
00040000
34
Brake overload
00080000
35
Motor phase U is missing
00100000
36
Motor phase V is missing
00200000
37
Motor phase W is missing
00400000
38
Fieldbus comm. fault
00800000
39
24 V supply fault
01000000
24
Mains failure
04000000
26
Brake resistor short circuit
08000000
27
Brake chopper fault
10000000
28
Option change
Frequency converter
20000000
29
initialization
40000000
30
Safe Torque Off
80000000
31
Mechanical brake low
Table 8.13 Parameter 16-90 Alarm Word
MG07F102
Programming Guide
Alarm
Bit (hex)
number
00000001
28
00000002
69
00000004
14
00000008
65
00000010
18
00000020
13
00000040
12
00000080
11
00000100
10
00000200
9
00000400
8
00000800
7
00004000
16
00008000
4
00010000
52
00040000
2
00080000
38
00100000
26
00400000
30
00800000
31
01000000
32
02000000
34
10000000
47
40000000
36
25
Table 8.14 Parameter 16-92 Warning Word
27
67
80
68
63
Danfoss A/S © 05/2016 All rights reserved.
Unit
Warning word
diagnoses
(parameter 16-92 Warning
bit
Word)
112
Brake check
Power card overtem-
113
perature
114
Ground fault
Control card overtem-
115
perature
116
Control word timeout
117
Overcurrent
118
Torque limit
Motor thermistor overtem-
119
perature
Motor ETR overtem-
104
perature
105
Inverter overloaded
106
DC-link undervoltage
107
DC-link overvoltage
110
Mains phase loss
111
No motor
96
Live zero error
98
Brake overload
99
Brake resistor short circuit
100
Brake chopper fault
102
Fieldbus comm. fault
103
24 V supply fault
88
Mains failure
89
Current limit
92
Encoder loss
94
Safe Torque Off
Alarm
number
28
69
14
65
18
8
8
13
12
11
10
9
8
7
4
3
2
26
25
27
34
47
36
59
61
68
53