Fault History And Statistical Data - Toshiba TE2 Series Instruction Manual

Low voltage digital solid state soft starter
Table of Contents

Advertisement

Fault code:
(See Chapter 7)
Time Stamp
(HH.mm)
Date Stamp
(MM.DD)
Table 5.6.12.a: Fault History Configuration
TE2 Series Digital Solid State Soft Starter User Manual

5.6.13 Fault History and Statistical Data

F085 - F097 contain the Fault History and Statistical data for the Run
Mode.
5.6.13.a Fault History
Fault codes for each of the three latest events are stored with time and
date stamps; see Chapter 7 for a complete list of fault codes and
corresponding error displays.
Time stamps use the 24hr HH.MM format, so for example 3:19 PM
would display as [15.19]
Date stamps use the MM.DD format, so for example September 3
would display [09.03]
Fault #1
(Latest Fault)
F085
F086
F087
F085 = Latest Fault Code (Fault #1)
Factory Setting = 0 (No Fault)
Range = 0 - 57
This Function displays the Fault Code of the latest fault event.
F086 = Time Stamp of the Latest Fault
Factory Setting = 00.00 (No Fault)
Range = 00.00 - 23.59 (24hr time format)
This Function displays the time of the latest fault event.
F087 = Date Stamp of the Latest Fault
Factory Setting = 00.00 (No Fault)
Range = 01.01 - 12.31
This Function displays the date of the latest fault event.
F088 = Same as F085 except for the Previous Fault (Fault #2).
F089 = Same as F086 except for the Previous Fault.
F090 = Same as F087 except for the Previous Fault.
F091 = Same as F085 except for the Oldest Fault (Fault #3).
F092 = Same as F086 except for the Oldest Fault.
F093 = Same as F087 except for the Oldest Fault.
Fault #2
(Previous Fault)
F088
F089
F090
58 |
P a g e
rd
Fault #3
(Oldest Fault)
F091
F092
F093

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents