Toshiba TE2 Series Instruction Manual page 94

Low voltage digital solid state soft starter
Table of Contents

Advertisement

Fn #
Group
Function Description
F019
Voltage Jog
F020
Time of Voltage Jog
F021
Current Jog
Fn #
Group
Function Description
F022
Kick Start Voltage
F023
Kick Start Time
Fn #
Group
Function Description
Pump Flex Control /
F024
Deceleration Ramp
Begin Decel Level (BDL),
F025
Immediate Drop Down
Torque
F026
Decel Shut Off Voltage
F027
Decel Ramp Time
Fn #
Group
Function Description
Restart Delay Time
F028
(Sequential Start Delay)
TE2 Series Digital Solid State Soft Starter User Manual
Adjustment / Display Range
5 - 100% Line Voltage
1 - 20 Seconds
100 - 500% Motor Current
Adjustment / Display Range
0 = Disabled, or
10 - 100% Line Voltage
0.1 - 2 Seconds
Adjustment / Display Range
0 = Disabled (coast to stop)
1 = Enabled, except after OL trip
2 = Enabled, continued Decel even
if there is an OL trip
0 - 100 % of Output Voltage
0 to (BDL minus 1)% Voltage
1 - 60 Seconds
Adjustment / Display Range
0 = Disabled, or
1-999 seconds after a Power Loss
(Status can be read in F054)
Setting
Factory
Increments
Setting
1%
50%
10
1 second
seconds
1%
150%
Setting
Factory
Increments
Setting
0
1%
Disabled
0.8
0.1second
seconds
Setting
Factory
Increments
Setting
0
1
Disabled
1%
60%
1%
30%
10
1 second
seconds
Setting
Factory
Increments
Setting
0
1 second
Disabled
85 |
P a g e
Setting
Setting
Setting
Setting

Hide quick links: