5:Technical Specifications; Table 5.2 Electrical Requirements - Emerson Branson 2000 Series Instruction Manual

Integrated welder
Table of Contents

Advertisement

100-214-251 IWoper.book Page 76 Friday, June 16, 2017 4:12 PM
5.1
Technical Specifications
5.1.1
Physical Description
The Branson 2000 Series Integrated Welders, IW and IW+ Models, are self-contained
ultrasonic plastics assembly systems that combine power supply, controls, indicators, and
welding stand in a compact bench unit. Its compact footprint conserves work space. It can
be used for ultrasonic welding, inserting, staking, spot welding, swaging, and degating
thermoplastic parts. It can be operated manually, semi-automated or automated systems.
The Integrated Welder's control system is microprocessor-based, and controls the welding
process while providing a level of user interface through a membrane keypad and alpha-
numeric display. It employs fan-forced cooling and it is intended for vertical placement.
The front panel display and user controls are intended to be accessible from a comfortable
position for and end user (operator), which means that the unit should be installed
approximately 3 feet off the floor.
The welder weighs approximately 145 pounds. For physical dimensions, refer to
2000IW/IW+ Integrated Welder Dimensional Drawing
Table 5.1
Environmental Specifications
Environmental Concern
Humidity
Ambient Operating Temperature
Storage / Shipping Temperature
Operating Altitude
IP Rating
5.1.2
Electrical Requirements
Table 5.2
Electrical Requirements
1100 W 100V - 120V
1100 W 200V - 240V
2200 W 200V - 240V
3300 W 200V - 240V
5.1.3
Pneumatic Requirements
The factory compressed air supply must be "clean (to a 5 micron level), dry and
unlubricated" air with a regulated maximum pressure of 100 psig (690 kPa). Depending
on your application, the welder requires between 35 to 100 psi. The welder includes an in-
76
30% to 95%, non-condensing
+5° C to +50° C (41° F to 122° F)
-25° C to +55° C (-13° F to +131° F);
up to +70° C (+158° F) for 24 hours
Up to 1000 m
2X
13 Amp Max. @ 100V / 17Amp CB
6.5 Amp Max. @ 200V / 8 Amp CB
14 Amp Max. @ 200V / 17 Amp CB
21 Amp Max. @ 200V / 20 Amp CB
Figure 4.4
Acceptable Range
NEMA 5-15P Plug
None supplied
None supplied
None supplied