4.4

Installation Requirements

This section covers the location options, dimensions of the major assemblies,
environmental requirements, electrical requirements and factory air requirements, to help
you plan and execute your installation successfully.
4.4.1
Location
The Integrated Welder should only be operated in the vertical position. The Welder (on a
base) is often manually operated, using its base-mounted start switches, and so is
installed at a safe and comfortable workbench height (approximately 30-36 inches) with
the operator sitting or standing in front of the system. Stands (on hubs) are often used in
automated systems and may be manually or automatically loaded and unloaded.
WARNING
The internal power supply module must be accessible for user parameter changes and
settings, so considerations must be made to be able to access the DIP switches. The
Welder should be positioned so it does not draw in dust, dirt or material via its internal
fan. Consideration should also be given to rear electrical and pneumatic connections,
approximately 6 in/150 mm. Refer to the illustrations on the pages that follow for a
dimensional drawing of each component. All dimensions are approximate and may vary
between models.
100-214-251 REV. 05
General Warning
The stand may tip over if moved around the axis of its column, if not
properly secured. The work surface on which a stand is installed must
be sturdy enough to support it, and secure enough to not tip over
when the stand is adjusted during installation or setup.