100-214-251 IWoper.book Page 47 Friday, June 16, 2017 4:12 PM
Table 4.3
Ambient Operating Temperature
Operating Altitude
IP Rating
4.4.3
Electrical Input Power Ratings
Plug the Welder into a single-phase, grounded, 3-wire, 50 or 60 Hz power source. lists
the current and fuse ratings for the various models.
Table 4.4
1100 W 100V - 120V
1100 W 200V - 240V
2200 W 200V - 240V
3300 W 200V - 240V
4.4.4
Factory Air
The factory compressed air supply must be "clean (to a 5 micron level), dry and
unlubricated" air with a regulated maximum pressure of 100 psig (690 kPa). Depending
on your application, the welder requires between 35 to 100 psi. Stands include an in-line
air filter. Welders on Stands require a customer-provided air filter. Use a lockout device on
the air line if required.
CAUTION
CAUTION
100-214-251 REV. 05
Environmental Specifications
Environmental Concern
Input Power Requirements
13 Amp Max. @ 100V / 17 Amp CB
6.5 Amp Max. @ 200V / 8 Amp CB
14 Amp Max. @ 200V / 17 Amp CB
21 Amp Max. @ 200V / 20 Amp CB
General Warning
Synthetic air compressor lubricants containing Silicone or WD-40 will
cause internal welder damage and failure due to the solvents
contained within these types of lubricants.
General Warning
There should be no substitute for clean, dry air to run the welder. Use
of other types of gas could lead to premature degradation of seals.
Contact your Branson representative if you have any concerns.
Acceptable Range
+5° C to +50° C (41° F to 122° F)
Up to 1000 m
2X
NEMA 5-15P Plug
None supplied
None supplied
None supplied