6.2

Setting Weld Cycle Parameters

When the welder is in the READY state, set parameters by pressing the appropriate
switches on the front panel. Once set, to store the current parameters, press one or both
START SWITCHES, or press RESET.
If you set parameters, start a weld cycle, then hit the EMERGENCY STOP before ending
the cycle, the parameters will be lost.
6.2.1
Selecting a Parameter to Modify
After selecting your weld mode by pressing MODE, press the appropriate switch for the
parameter you wish to modify. For example, press MODE for the Time, Collapse or
Absolute parameters, press HOLD TIME for the Hold Time parameter, then press the
appropriate LIMIT switch to set limits, if necessary.
As you press a switch, its LED will light and the selected parameter's value will be
displayed in the NUMERIC display.
6.2.2
Modifying Parameter Values
Press the UP/DOWN switches until the value you wish to modify is displayed in the LED
display. Effects of pressing these switches are illustrated in the following Table. In the
Increment Values column, the left side figures indicate effects of pressing SLOW UP/
DOWN switches, while the right side figures indicate effects of pressing FAST UP/DOWN
switches.
If you press an UP/DOWN switch after pressing a parameter selection switch except
MODE, the next press of the parameter selection switch will set the parameter you
selected to is original value. Then the next press will set the parameter to its minimum
value.
Note that you can recall a parameter after you have changed it, but only either before a
weld cycle is run, or before you select another parameter to modify. (For further
information, refer to Section
Table 6.7
Weld Parameter Values IW+ only
Parameter
Weld Time
+ Limit
- Limit
Hold Time
AB Delay
AB Time
Collapse
+ Limit
- Limit
Absolute
+ Limit
92
6.2.4 Recalling Stored
Range
Range
Increment Values
Min
Max
SLOW/FAST
.050
10.0
.001/.100
.050
10.0
.001/.100
.050
10.0
.001/.100
.050
10.0
.001/.100
.050
5.00
.001/.100
.050
1.00
.001/.100
.0001
0.25
.0001/.0100
.0001
0.25
.0001/.0100
.0001
0.25
.0001/.0100
.0001
4.00
.0001/.0100
.0001
4.00
.0001/.0100
Parameters.
Can be
Units
Disabled
sec
No
sec
Yes
sec
Yes
sec
No
sec
Yes
sec
Yes
inch*
No
inch*
Yes
inch*
Yes
inch*
No
inch*
Yes
100-214-251 REV. 05
Can be
Recalled
No
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
No
Yes

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Branson 2000iw+

Table of Contents