Ultrasonic Test - Emerson Branson 2000 Series Instruction Manual

Integrated welder
Table of Contents

Advertisement

100-214-251 IWoper.book Page 108 Friday, June 16, 2017 4:12 PM
6.7

Ultrasonic Test

Use the TEST switch on the front panel to measure the ultrasonic energy dissipated by the
stack in air, as long as the welder does not overload. When a welder is operating correctly,
the power dissipated by one specific stack in air should be consistent (±) over a long
period of time. Any change in power indicates that a problem could be developing.
If an overload occurs, and the stack is known to be mechanically sound, the welder may
require manual tuning. (For further information, refer to Section
To test the welder, make sure that the stack is properly assembled and that all
connections have been made correctly. Then press TEST.
CAUTION
WARNING
Ultrasonic energy will remain on as long as TEST remains pressed and the welder does not
overload. Pressing TEST causes the POWER BARGRAPH to switch to the DIP Switch-
selected multiplier (for further information, refer to Section
After 4 to 6 seconds, the Autotune feature is disabled and the welder enters manual
tuning mode (for further information, refer to Section
point on, tuning is controlled by the tuning potentiometer.
108
General Warning
You must have a converter-booster-horn stack installed in you welder
before activating ultrasonic energy.
General Warning
Ensure that the cover is closed with the door screws secured and that
no one is in contact with the horn when you press TEST. Automated
systems users should turn off indexing equipment for this test.
7.4.1 Manual
Tuning.)
4.11.1 Setting DIP
Switches).
7.4.1 Manual
Tuning). From this
100-214-251 REV. 05