Table 4.5 Options for Setting the Type 1 Switch Select Block
Function
Amplitude
Control
Start
** The default Start setting is "Standard".
Figure 4.15Type 2 DIP Switch Marked "ON" on face of Switch, Default Settings.
NOTICE
Toggle 5 is not used.
Options for Setting the Type 2 Switch Select Block
Table 4.6
Options for Setting the Type 2 Switch Select Block
Functions
Seek
58
Option
–
Auto Seek Duration
Indicates the length of
time the Auto Seek function is active.
–
Store at End of Weld
Updates horn frequency
memory at the end of each weld.
Set for Fixed 100% Amplitude, Variable turned
Off
–
Short
Sets ramp time to 10 ms.
–
Medium
Sets ramp time to 35 ms.
–
Standard**
Sets ramp time to 80 ms.
–
Long
Sets ramp time to 105 ms.
Options
–
Seek on power up
Checks horn frequency upon
power up and stores it in memory.
Set Toggles
3 – Down (500 ms)
3 – Up (100 ms)
4 – Down (Off)
4 – Up (On)
6 – Down (Off)
7 – Down
8 – Down
7 – Up
8 – Down
7 – Down
8 – Up
7 – Up
8 – Up
Set Toggle
1 – Down (Off)
1 – Up (On)