100-214-251 IWoper.book Page 57 Friday, June 16, 2017 4:12 PM
4.5.7
Power Supply Module Options DIP Switch
DIP switch changes the Seek and Start functions and can affect the Amplitude Control
functions.
There are two DIP switches that Branson uses interchangeably. The following Figures
illustrate each of them. Default operational settings are provided in the Tables.
CAUTION
WARNING
Figure 4.14Type 1 DIP Switch Marked "OPEN" on Top of Switch, Default Settings.
NOTICE
Toggle 5 is not used
Table 4.5 Options for Setting the Type 1 Switch Select Block
Function
Seek
100-214-251 REV. 05
General Warning
The components in the Power Supply section of the Integrated
Welder are subject to damage from electro-static discharge. When
working inside the Integrated Welder, use a grounded wrist strap and
minimize your movement to reduce the possibility of damage due to
static electricity.
General Warning
Unplug the welder (if previously connected) and wait at least two (2)
minutes before opening the case. Hazardous Voltages exist and are
stored in the system.
Option
–
Seek on power up
Checks horn frequency upon
power up and stores it in memory.
–
Auto Seek
Checks horn frequency once each
minute, timed from the last activation of
ultrasonics.
Set Toggles
1 – Down (Off)
1 – Up (On)
2 – Down (Off)
2 – Up (On)
57