Display - error messages

During tractor operation, three types of error messages may appear in the display.
A. - Warning of operational protection,
that a small deviation from the set values or error by the operator occurred.
The warning is displayed in the display for about 10 seconds and then the display is switched to the
previously set main screen.
The state is indicated by the signal lamp
The tractor can be used without limitation.
B. - Less serious defects of the system
If a less serious defect of the system occurs, the defect number is displayed in the display for about 10
seconds. Then the display of the defect is minimized into the main field.
All the tractor's functions remain active; it can happen that some of the functions is not undepreciated.
The state is indicated by the signal lamp
If this situation occurs, finish the work and contact the service centre.
C. - Serious defects of the system
If a serious defect occurs, the display is backlighted in red there is a label STOP. The display cannot be
switched to another screen.
The state is indicated by the signal lamp
If this situation occurs, stop the tractor immediately and contact the service centre.

Description of the display of error messages

1 - The symbol of the defect significance.
2 - Node of the tractor where the defect appeared.
3 - Main display field - defect code.
4 - Secondary display field - defect specification.
DASHBOARD
C15N057
52
C15N056