Class 82/Parameters
IP address 5 for ping test
Connection timeout for a failed
GPRS login attempt
Number of dialling attempts to
GPRS service before module
reset
Server timeout until disconnect
Waiting time after x failed GPRS
login attempts
Ping port (TCP sync)
ZDUE-GPRS-PLUS-VI
Offset
Len
Values (ASCII)
'0' .. '9' and '.'
178
15
'000' .. '999'
193
3
'0' .. '9'
196
1
'000' .. '300'
197
3
'001' .. '999'
200
3
203
5
5 characters
'0' .. '9'
208
GPRS Modes
Description
Destination IP of a potential
communication partner for a
ping
e.g.: '062.109.255.003'
Def.: '000.000.000.000'
Time in seconds after which a
GPRS login is repeated after a
failed attempt.
Def.: '300'
Number of attempts to login to
the GPRS service before the
module is reset.
Def.: '3'
Time in seconds after which the
module automatically terminates
the TCP server service.
'000': Module remains logged
into the service continuously
Def.: '000'
Time in minutes that have to go
by after a login error (incl.
repetitions) before the GPRS
module tries to log in again.
Def.: '060'
Port on which the "IP ping"
(TCP sync) is performed.
'00000'..'65535'.
Def.: '00080'
Page 53 of 63