6 Configuration

The most important
configurable
settings and
functions

6.1 Configuration by software

Remote
configuration via
the GSM network
Local configuration
ZDUE-GPRS-PLUS-VI
Security settings
Password
Data format and transmission speed of the meter interfaces
GSM module reset
Configuration is performed with the software that is used for operation of the
control centre or a configuration software (e.g. Dr. Neuhaus ZDUEset).
Parameterisation commands are transmitted to the ZDUE-GPRS-PLUS-VI
with the aid of this software.
The software commands are described starting on page 33.
The parameterisation commands can be transmitted to the ZDUE-GPRS-
PLUS-VI via the GSM network (remote configuration) or directly via the RS-
232 interface (local configuration).
Remote configuration is performed by the control centre, which transmits
parameterisation commands to the ZDUE-GPRS-PLUS-VI via the GSM
network. Transmission takes place according to DIN EN 62056-21 with BCC
secured protocol.
The parameterisation commands must be transmitted explicitly to the
address of the
ZDUE-GPRS-PLUS-VI.
The following device address is preset at the factory: 99999999
The device address is configurable. It can contain up to 16 characters;
numbers and letters are permitted.
The device can also be configured with the aid of a computer that is
connected via its COM port directly to the RS-232 interface of the ZDUE-
GPRS-PLUS-VI.
Precondition:
No GSM connection exists between ZDUE-GPRS-PLUS-VI and control
centre.
GSM offline status: Settings of the RS-232 interface
As soon as no GSM connection exists, the RS-232 interface is set by default
to the following setting:
19200 baud
8 data bits, No Parity, 1 stop bit
Configuration
Page 27 of 63