ZDUE-GPRS-PLUS-VI
Read position of the DIP switch/parameter status
Command format: <SOH>R3<STX>S96(15)<ETX><BCC>
Reply (example):
<STX>S96(15)(ccccp)<ETX><BCC>
The parameters have the following meaning here:
cccc :
Hex-coded 16-bit output
p :
Parameter status flag:
0 : User parameterisation active
1 : Default parameterisation active
This command is also permitted for the GSM interface.
Read GSM operating/module parameters:
Command format: <SOH>R3<STX>S65( )<ETX><BCC>
Reply (example):
<STX>S65(dB)(Net-ID)(location)(Cell ID) (IMEI) (IMSI)
<ETX><BCC>
The parameters have the following meaning here:
GSM field strength (3-digit, decimally coded, e.g.: '075' => -
dB
75dBm, 'na' => not available)
Net ID
Network ID of the GSM network operator (max. 6 digits, e.g.:
'26202'),
Location
GSM Location Area ID (max. 4-digit, hex-coded),
Cell ID
GSM Cell D (max. 4 digits, hex-coded),
IMEI
Serial number of the GSM module (International Mobile
station Equipment Identity, max. 20 digits),
IMSI
ID number of the SIM card (International Mobile station
Equipment Identity, max. 20 digits).
This command is also permitted for the GSM interface.
Example (reply):
<STX>S65(075)(26202)(019B)(6434)(35704200045977
7) (262023800175922)<ETX>