7 ND90 71 en
ND9100H - Dev v4, DD v2:
Device Information:
1 Device Information
1 Operation Unit
2 Confguration
2 Positioner
3 Calibration
4 Manually Stroke Valve
5 Monitoring
6 Lifecycle Diagnostic
7 Counter Diagnostics
8 Online Diagnostics
9 Valve Offline Tests
Advanced Configuration
Configuration
1 Position Control
2 Assembly Related
3 Signal Modification
MENU
METHOD
Editable variable
Read-only variable
Calibration
1 Automatic Calibration
2 One Point Calibration
Manually Stroke Valve
Manual mA Setpoint
Manual percent Setpoint
Monitoring
1 Loop Current
2 Setpoint
3 Target Position
4 Valve Position
5 Device Temperature
6 Supply Pressure
7 Actuator Pressure Difference
Lifecycle Diagnostic
1 Warning Limits for Trends
Counter Diagnostics
1 Counters
2 Warning Limits for Counters
Online Diagnostics
1 Device Status
2 Alarm Limits
3 Events
Valve Offline Tests:
1 Start Offline Tests
2 Test Key Figures
Operation Unit
1 Tag
2 Description
3 Date
4 Message
5 Long tag
Positioner
1 Device Type
2 VC PCB Serial Number
3 HART PCB Serial Number
4 Device Serial Number
5 HART Board HW revision
6 Software rev
7 HART Board Dac SW revision
Position Control
Aggressive (A);Fast (b); Optimum (C);Stable (d); Maximum Stability (E); Capacity Booster, Aggressive (A1); Capacity Booster, Fast
Performance Level
Assemby Related
1 Actuator Type
2 Valve Acting Type
3 Valve Rotation Direction
4 Dead Angle (a0)
5 Positioner Fail Action
6 Positoner Transmitter Directions
Signal Modification
1 Direction
2 Valve Position Limit LOW
3 Valve Position Limit High
4 Travel Rate Open
5 Travel Rate Close
6 Low Cut-Off
7 High Cut-Off
8 Split Range LOW
9 Split Range HIGH
Bypass signal modification
Automatic Calibration
1 Start Automatic Calibration
One Point Calibration
1 Start One Point Calibration
Warning Limits for Trends
1 Steady State Deviation
2 Dynamic State Deviation
3 Stiction Low
4 Stiction High
5 Load for Open Low
6 Load for Open High
Counters
1 Total Operation Time
2 Total Valve Travel
3 Total Valve Reversals
4 Total Actuator Travel
5 Total Actuator Reversals
6 Total Spool Valve Travel
7 Total Spool Valve Reversals
8 Total Setpoint Travel
9 Total Setpoint Reversals
Warning Limits for Counters
1 Total Operation Time
2 Total Valve Travel
3 Total Valve Reversals
4 Valve Reversals Trend
5 Daily Valve Reversals while Stable Setpoint
6 Total Actuator Travel
7 Total Actuator Reversals
8 Total Spool Valve Travel
9 Total Spool Valve Reversals
Setpoints Reversals Trend
Device Status
Alarm Limits
1 Steady State Deviation
2 Supply Pressure
3 Temperature
4 Stiction
5 Load for Opening
6 Valve Position
Events
1 All Events
2 Notify Events
3 Warning Events
4 Error Events
5 Alarm Events
6 Failsafe events
Select which Offline Test to start:
1 Multipoint Step Test
2 Dynamic Loop Test
3 Valve Analysis Test
4 Valve Deadband Test
Test Key Figures:
1 Multipoint Step Test Key Figures
2 Dynamic Loop Test Key Figures
3 Valve Analysis Test Key Figures
4 Valve Deadband Test Key Figures
ND9000
ND9000
27.8.2001
ND9000
ND9000
ND9100H
1650518510
1647317020
PH17100205
H033592-1.20
193
UNKNOWN
(b1); Capacity Booster, Optimum (C1);Capacity Booster, Stable (d1)
Double Acting, Single Acting
Rotary, Linear with Compensation, nelesCV Globe, Linear without Compensation
Clockwise to Close, Counterclockwise to Close
0,00 %
Close, Open
Normal Direction, Reverse Direction, Not Installed
Rising Setpoint to Open, Rising Serpoint to Close
0,00 %
100,00 %
0,00 %
0,00 %
2,00 %
100,00 %
0,00 %
100,00 %
No; Yes
3,00 %
20,00 %
0.0 bar
4.0 bar
0.0 bar
0.0 bar
1.10 h
0,04
0
0,04
0
0,02
0
0,18
0
216000.0h
250000
1000000
10000
5000
250000
1000000
10000000
10000000
10000
List active alerts
67
Steady State Deviation
1 Steady State Deviation High Limit
5 %
2 Steady State Deviation Latch Time
30sec
Supply Pressure
1 Supply Pressure Low Limit
1.4 bar
2 Supply Pressure High Limit
8.0 bar
3 Supply Pressure Latch Time
30 sec
Temperature
1 Temperature Low Limit
-40.0 deg C
2 Temperature High Limit
85.0 deg C
3 Temperature Latch Time
120.0 sec
Stiction
1 Stiction Low Limit
0.0 bar
2 Stiction High Limit
10.0 bar
3 Stiction Latch Number
10
Load for Opening
1 Load for Opening Low Limit
0.0 bar
2 Load for Opening High Limit
0.0 bar
3 Load for Opening Latch Number
10
Valve Position
1 Valve Position Low Limit
-20.0%
2 Valve Position High Limit
120.0%
3 Valve Position Latch Time
30.0 sec
Multipoint Step Test Key Figures:
1 Start Position
50.00
2 End Position
55.00
3 Testing Time
5.00
4 Dead Time Td
0.08
5 Step Response Time T86
0.62
6 Overshoot
1.17
7 Travel Gain
1.00
Dynamic Loop Test Key Figures:
1 Start Position
0.00 %
2 End Position
100.00 %
3 Total Testing Time
30.00 sec
4 Max. Dyn. Error
3.67 %
5 Setpoint at Error
87.07 %
Valve Analysis Test Key Figures:
1 Target Position
50.0 %
2 Steady Time
12.0 sec.
3 Ramp Time
30.0 sec.
4 Static Hysteresis
1.2 %
5 Sensitivity
5.2 %
6 Load for Opening
0.6 bar
7 Seat Load
4.8 bar
8 SR O2C Close
0.0 bar
9 SR O2C Open
0.0 bar
SR C2O Close
0.0 bar
SR C2O Open
0.0 bar
Valve Deadband Test Key Figures:
1 Start Position
50,00 %
2 Testing Time
10
3 Deadband
0.1

Hide quick links: