Suzuki Wagon R Manual page 2346

Hide thumbs Also See for Wagon R:
Table of Contents

Advertisement

Unit Repair Overhaul
Removal and installation
For G10 Engine
Refer to "Unit Repair Overhaul" in the same section of the Service Manual mentioned in FOREWORD of this
manual.
For M13 Engine
1. "B" terminal wire
3. Generator bolt
2. "B" terminal nut
4. Generator belt
Generator
Rated voltage
Nominal output
Permissible max. speed
No-load speed
Setting voltage
Permissible ambient
temperature
Polarity
Rotation
Load Check
1) Run engine at 2,000 rpm and turn on head light and heater
motor.
2) Measure current and if it is less than 20 A repair or replace
generator.
5. Splash cover
Tightening torque
6. Generator
Specifications
70 A
14.4 to 15.0 V (at 20°C (68°F)
–30 to 100°C (–22 to 212°F)
Clockwise viewed from pulley side
CHARGING SYSTEM (G10/M13 ENGINES) 6H-3
12 V
18000 r/min.
1300 r/min (rpm)
14.2 to 14.8 V (at 25°C (77°F)
Negative ground
75 A

Hide quick links: