7B1-104 AUTOMATIC TRANSAXLE (M13 ENGINE)
Timing solenoid valve
CAUTION:
Do not insert air gun against strainer installed on inlet of
solenoid valve too deeply, when blowing air into solenoid
valve. If not, the strainer will be damaged.
• Check that solenoid valve (1) actuate with click sound when
battery voltage is conducted.
• When timing solenoid valve (1) is connected to battery (2),
confirm that timing solenoid valve is open condition by blow-
ing air (50 – 200 kPa, 0.5 – 2.0 kg/cm
solenoid valve as shown in the figure.
• When timing solenoid valve (1) is not connected to battery
(2), confirm that timing solenoid valve is close condition by
blowing air (50 – 200 kPa, 0.5 – 2.0 kg/cm
solenoid valve as shown in the figure.
NOTE:
Do not fail to inspect with air to prevent mistaken check-
ing because return spring for valve is not installed into
solenoid valve.
2
, 7 – 28.5 psi) into
2
, 7 – 28.5 psi) into