2. Bright Pixel
Procedure
Inspection item
Criteria
3. Dark Pixel
Procedure
Inspection item
Criteria
4. Bright Blemish
Procedure
Inspection item
Criteria
CLM W6_CLM HD6 Jan 3, 202
Chapter 4 Function Test & Alignment Procedure
- The PC mode functionally should be workable
include support format with frequency and auto
detected functional will be workable.
- Test equipment: video generator
- Test signal: 920 x 080 @60Hz
- Test Pattern: Gray 0
- Bright pixel check
- Bright pixel is unacceptable in the active zone
for CLM HD6,  pixel is allowed for CLM W6.
 pixel is allowed on the frame for all.
pixel is allowed on the frame for all.
- Adjacent pixels are unacceptable.
- Ref. Defect specification table
- Test equipment: video generator
- Test signal: 920 x 080 @60Hz
- Test Pattern: Full white
- Dark pixels check
- The dark pixel should be no more than 6 under
full white pattern.
- Adjacent pixels are unacceptable.
- Ref. Defect specification table
- Test equipment: video generator
- Test signal: 920 x 080 @60Hz
- Test Pattern: Gray 5
- Bright blemish check
- The bright blemish should be no more than 0
under gray 5 pattern.
- Ref. Defect specification table
Gray 10
Full white
Gray 15
4-7