Machine Data and Incremental Dimensions
Data Used in the Parameter DB
Address
Name
100.0
CHGDIF_P
104.0
CHGDIF_M
108.0
CUTDIF_P
112.0
CUTDIF_M
8.8.3
Incremental Dimension Number 255
Incremental dimension number 255 also allows you to set the distance.
You transfer the switch-off differences and the switchover differences together with
the incremental dimension. In contrast to the other incremental dimensions,
incremental dimension 255 uses the value for the switch-off and switchover
difference specified in the channel DB. The entries from the machine data have no
validity for this incremental dimension.
Data Used in the Channel DB
Address
Name
36.3
TRG255_EN
100.0
TRG255
104.0
CHGDIF255
108.0
CUTDIF255
8-26
Type
Initial Value
DINT
L#5000
DINT
L#5000
DINT
L#2000
DINT
L#2000
Type
Initial Value
BOOL
FALSE
1 = write incremental dimension for
incremental dimension number 255
DINT
L#0
Incremental dimension for incremental
dimension number 255
DINT
L#0
Switchover differences for incremental
dimension number 255
DINT
L#0
Switch-off differences for incremental
dimension number 255
Comment
Switchover difference plus
Switchover difference minus:
Switch-off difference plus
Switch-off difference minus
Comment
FM 351 Positioning Module