Assembly Of The Measurement Ball Valve; Assembly Without Flow Meter, But With Screw Cap Instead (Blind Cap); Shut Off The Measurement Ball Valve - E+E Elektronik EE771 Series Manual

Flow meter for compressed air and gases
Table of Contents

Advertisement

3.5.

Assembly of the measurement ball valve

All connections to be made with appropriated sealing material on the threads.
The sealing material should not change the area of the inner cross section of the pipe. It must be
warranted that the connections after installation are free of leaks.
All fittings must be tested on seal tightness.
Make sure during the assembly of the measurement section that the arrows on the pipe section
and the measurement ball valve are pointing in the same direction as the flow.
The recess for the alignment pin must be at the side of the outlet.
recess for
alignment pin
3.5.1.

Assembly without flow meter, but with screw cap instead (blind cap)

In order to use the measurement section without the flow meter, the blind screw cap (in
the scope of supply) must be screwed tight onto the opening of the measurment ball
valve. If not needed the screw cap can be screwed and stored on the handle of the
measurment valve with shut-off function.
3.5.2.

Shut off the measurement ball valve

The measurment ball valve assembly allows for the installation and removal of the flow meter within seconds,
with only a very short interruption of the flow.
OPEN
CLOSED
11
Never remove the flow meter
or the blind screw cap while
the measurement ball valve
is open.
That is extremely danger-
ous!

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ee771-bEe771-aEe771-c

Table of Contents