3) Outside Rearview Mirror (OSRVM)
Mirror Position Control
-
The position sensor senses the changes of motors in the mirrors.
-
The mirror position is stored by the memory order of position switch.
-
The mirror position is recalled by the recall order of position switch.
-
The manual adjustment of mirror positions takes priority over the memory and recall orders.
Motor Drive Control
-
Driving sequenceHorizontal → Vertical
-
Control during memory reca
·
Horizontal direction : 1.5 ~ 3.7 V
Vertical direction : 1.5 ~ 3.7 V
·
Field of vision :
The control range of mirror that is notlimited mechanically.
·
The control range of that doesn't affectthe sensor characteristics
·
-
LOCK detection
Timer monitors the motor driving time to detect LOCK condition.
·
-
Monitoring the memory recall time
If the memory recall operation cannot be finished within 40 seconds after activating it,
·
the system stop themotor output and terminate the control.
Error Detection
Even though the motor runs, if the drive input change (for 5 seconds) from the position
sensor doesn't change, it isdetermined that the harness circuit is open or the motor/sensor
failure occurred.When an error is detected, any memory set or recall operations are
prohibited, but the manual operation is possible.When the sensor input changes by a
manual operation, this error is cleared.
Specification
-
Rated voltage : DC 12 V
-
Operating voltage : DC 9 ~ 16 V
-
Current consumption : Max. 300 mA (not including the load)
-
Operating temperature range : -30°C ~ 75°C
-
Reserve temperature range : -40°C ~ 85°C