01-24
6810-15
2) Coolant Circulating Route
3) Connecting the Coolant Circuit
The heater is connected to the coolant circuit in the coolant feed pipe from the vehicle engine to
the heat exchanger.
-
Parts conveying coolant must be routed and fastened in such a way that they pose no
temperature risk to
person or material sensitive to temperature from radiation and direct contact.
-
Before working on the coolant circuit, disconnect the negative battery cable and wait until
all components have cooled down completely.
-
When installing the heater and the water pump, note the direction of flow of the coolant
circuit.
-
Fill the heater and water hoses with coolant before connecting to the coolant circuit.
-
When routing the coolant pipes, observe a sufficient clearance to hot vehicle parts.
-
Protect all coolant hoses/coolant pipes from chafing and from extreme temperatures.
-
Secure all hose connections with hose clamps.
AIR CONDITIONER