2-Electrode Conductivity - ABB AWT210 Operating Instruction

2-wire conductivity, ph/orp pion transmitter
Hide thumbs Also See for AWT210:
Table of Contents

Advertisement

AW T 2 1 0 | 2 - W I R E C O N D U C T I V I T Y, P H/O R P, P I O N T R A N S M I T T E R | O I/A W T 2 1 0 - E N R E V. C

2-electrode conductivity

Menu
Easy Setup
Exit
Select
Menu
Comment
Language
Selects the language to be displayed on screen:
English/Deutsch/Français/Español/Italiano
Note. The language options are displayed with localized spelling.
Measurement Type
Selects a measurement type compatible with the connected sensor:
Conductivity/Concentration
Cell Constant
Used to adjust the slope of the calculation graph.
The design of the conductivity sensor determines the sensor constant (usually k = 1).
Conc . Unit
Sets the process value units.
Enabled only if Measurement Type = Concentration.
%/ppm/ppb/µg/l/mg/l
Conc . Curve Name
Enabled only if Measurement Type = Concentration.
Temp . Unit
Temperature unit displayed and applied to all temperature parameters/values.
Not enabled if Temperature Compensation Type = Manual.
°F/°C
Operator Page 1
Selects range of values displayed on Operator Page 1 – see page 47 for examples of character formats/sizes.
PV/PV + Temperature/PV + Temp + PV%/PV + Temp + O/P
Used to setup standard parameters quickly.
Note. Easy Setup menus are sensor-specific – the menus in this section are applicable to
transmitters connected to 2-electrode conductivity sensor types.
29
Default

Advertisement

Table of Contents
loading

Table of Contents