MAXA HI-T User's And Installer's Manual page 22

Lcd touch-screen centralized controller for hydronic terminal coupled with n-i-hwak/wp v2/v2+ minichillers and i-hp/i-hp lt chillers
Table of Contents

Advertisement

3.1.2. Chiller 02 
3.1.3. Chiller xx 
3.2. Keyboard 
3.3. Fan coil 
4. Alarm  list 
 
The  service's  parameters  of  the  chiller  correspond  to  those  listed  in  the  user‐installer  manuals  of  the  minichiller/heatpumps  i‐
HWAK/WP V2/V2+ and of the chiller/heat pumps i‐HP. 
The service parameters of the keyboard are shown in the following table: 
 
N. 
1/44 
Communication timeout 
2/44 
Maintenance PSW 
3/44 
Min FC cooling setpoint 
4/44 
Max FC cooling setpoint 
5/44 
Min FC heating setpoint 
6/44 
Max FC heating setpoint 
7/44 
Keypad address 
8/44 
Number of chiller in network 
9/44 
Rotation time 
10/44  Diff. Between units 
11/44  Set Text comp CHIL Cool 
12/44  Set Text comp CHIL Heat 
13/44  m1 coefficient for compensation Text CHIL in cool with low 
temp. 
14/44  m2 coefficient for compensation Text CHIL in cool with 
high temp. 
15/44  m3 coefficient for compensation Text CHIL in heat with low 
temp. 
16/44  m4 coefficient for compensation Text CHIL in heat with 
high temp. 
17/44  Set Text comp FC Cool 
18/44  Set Text comp FC Heat 
19/44  m5 coeff for compensation Text Fan Coil cool 
20/44  m5 coeff for compensation Text FanCoil heat 
21/44  Set2 Text cmp CHIL Cool 
22/44  Set2 Text cmp CHIL Heat 
23/44  m1 coefficient for compensation Text CHIL in cool with low 
temp., double set‐point 
24/44  m2 coefficient for compensation Text CHIL in cool with 
high temp., double set‐point 
25/44  m3 coefficient for compensation Text CHIL in heat with low 
temp., double set‐point 
26/44  m4 coefficient for compensation Text CHIL in heat with 
high temp., double set‐point 
27/44  ID su 15‐16 
28/44  Enable Beep 
29/44  Installer Psw Timeout 
30/44  Installer Psw exit time 
31/44  Legionella disinfection eneable time 
32/44  User Password 
33/44  Enable user  alarm log 
34/44  Idle Backlight intensity 
35/44  Screensaver unlockPsw 
36/44  Screed function Set 
37/44  Duration screed function 
38/44  Timeout LCD Navigation 
39/44  Thermostat t decalibration 
40/44  Thermostat unit probe decalibration 
21 
 
PARAMETERS NAME 
 
UNIT 
DEFAULT 
VALUE 
Numb 
120 
Numb 
°C 
15.0 
°C 
45.0 
°C 
5.0 
°C 
45.0 
Numb 
100 
Numb 
Minutes 
30 
°C 
2.0 
°C 
20.0 
°C 
10.0 
0.0 
Numb 
0.0 
Numb 
0.0 
Numb 
0.0 
Numb 
°C 
25.0 
°C 
15.0 
Numb 
0.0 
Numb 
0.0 
°C 
20.0 
°C 
10.0 
0.0 
Numb 
0.0 
Numb 
0.0 
Numb 
0.0 
Numb 
Numb 
Numb 
Minutes 
Minutes 
20 
Minutes 
60 
Numb 
Numb 
Numb 
°C 
35.0 
Ore 
10 
Seconds 
60 
°C 
0.0 
0.0 
 
  Hi‐T
Centralized controller
MINIMUM 
VALUE 
10  
0  
1.0  
1.0  
1.0  
1.0  
100  
0  
0  
1.0  
0.0  
‐20.0  
‐10.0  
‐10.0 
‐10.0  
‐10.0  
0.0  
‐20.0  
‐10.0  
‐10.0  
0.0  
‐20.0  
‐10.0  
‐10.0  
‐10.0  
‐10.0  
0  
10 
35.0 
30 
‐10.0 
‐10.0 
MAXIMUM 
VALUE 
255 
999 
60.0 
60.0 
60.0 
60.0 
130 
800 
60.0 
50.0 
35.0 
10.0 
10.0 
10.0 
10.0 
50.0 
35.0 
10.0 
10.0 
50.0 
35.0 
10.0 
10.0 
10.0 
10.0 
120 
120 
600 
999 
100 
999 
55.0 
100 
300 
10.0 
10.0 