Manufacturer's Information; Transport; Delivery And Performance; Storage - Gemu 605 Installation, Operating And Maintenance Instructions

Diaphragm valve metal, dn 4 - 15
Table of Contents

Advertisement

Available languages

Available languages

Control function
Normally closed
Normally open
Double acting
Valve body surface fi nish, internal contour
Ra ≤ 6.3 μm
blasted internal/external
Ra ≤ 6.3 μm
electropolished internal/external
Ra ≤ 0.8 μm
mechanically polished internal, blasted external
Ra ≤ 0.8 μm
electropolished internal/external
Ra ≤ 0.6 μm
mechanically polished internal, blasted external
Ra ≤ 0.6 μm
electropolished internal/external
Ra ≤ 0.4 μm
mechanically polished internal, blasted external
Ra ≤ 0.4 μm
electropolished internal/external
Ra ≤ 0.25 μm
mechanically polished internal, blasted external
Ra ≤ 0.25 μm
electropolished internal/external
Ra acc. to DIN 4768; at defined reference points
Order example
Type
Nominal size
Body configuration (code)
Connection (code)
Valve body material (code)
Diaphragm material (code)
Control function (code)
Actuator size (code)
Surface finish (code)
8

Manufacturer's information

8.1

Transport

Only transport the diaphragm valve
G
with suitable means, do not drop it and
handle it carefully.
Dispose of packing material
G
according to relevant local or national
disposal regu-lations / environmental
protection laws.
8.2

Delivery and performance

Check the goods for completeness and
G
damages immediately upon receipt.
The scope of delivery is apparent from
G
the dispatch documents and the design
from the order number.
605_us
Code
(NC)
(NO)
(DA)
605
605
Actuator size
Diaphragm size 8
1
2
3
* only investment cast design
8
D
60
8
D
60
The valve's delivery condition:
G
Control function:
1 Normally closed (NC)
2 Normally open (NO)
3 Double acting (DA)
The function of the diaphragm valve is
G
checked at the factory.
8.3

Storage

Store the diaphragm valve so that it is
G
dust protected and dry in its original
packaging.
Avoid UV rays and direct sunlight.
G
Maximum storage temperature: 40°C.
G
Solvents, chemicals, acids, fuels or the
G
like must not be stored in the same room
as valves and their spare parts.
20 / 34
34
3A
1
34
3A
1
Code
0/N
Code
1500*
1509*
1502
1503
1507
1508
1536
1537
1527
1516
0/N
1500
0/N
1500
Status:
closed
open
undefi ned