Description Of Minor Errors Of The Ehr-B Electro-Hydraulic System - Zetor PROXIMA HS Series Operator's Manual

Table of Contents

Advertisement

Description of minor errors of the EHR-B electro-hydraulic system

Flashing combination of
the diagnostic LED (7).
No.
Long
Short
of
pause
pause
flashes
3x
3x
3x
3x
Outer hydraulic circuit
It supplies pressure oil for hydraulic devices on outer
drives of hydraulics ended with couplers. Coupler sockets
with 12.5 mm bore are in accordance with the international
recommendation of ISO.
ELECTRO-HYDRAULIC SYSTEM
Error location
No.
of
flashes
1x
Right dynamometric pin
(A)
2x
Left dynamometric pin (A) Faulty contact or interrupted conductor of the
4x
Lowering speed control
(3)
6x
Control setting switch (6)
F_02_174
Possible cause of the error
Faulty dynamometric pin
dynamometric pin
Short-circuit of the dynamometric pin
conductor
Possible overloading of the dynamometric
pin
Faulty potentiometer of the control (3)
Faulty contact or interrupted conductor of the
control
Faulty potentiometer of the switch (6)
Faulty contact or interrupted conductor of the
switch
132
P+13N011

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proxima hs 110Proxima hs 100Proxima hs 120